Heller Oven 1809 lubricant

Electronics Forum | Mon May 09 09:25:51 EDT 2016 | jorgenino

Hello I am new to SMT line maintenance. I was wondering what a good option is for a lubricant that we can use in our Heller reflow oven. Especially the witdh adjusting lead screw. The manual recommends Krytox but does not state a specific one. Thanks

Heller MK5 13 Zone Conveyor Adjust

Electronics Forum | Fri Jun 18 09:53:51 EDT 2021 | shmevan91

Hi, we have checked all of those and beenm in contact with heller but they said they will need to send an engineer out as they are also out of ideas, was hoping someone might've had the same issues as we have two ovens doing the same thing, wont move

HELLER 1800W ELEMENTS

Electronics Forum | Wed May 30 19:08:58 EDT 2007 | darby

Mark, You should find that the blower motors and heaters will be replaced free of charge by Heller. I have four Heller ovens and have found that to be the case. I am the original purchaser however and it may be different if you have purchased the mac

Interference to lights from Heller 1707 XL oven

Electronics Forum | Mon Sep 14 20:19:33 EDT 2020 | kumarb

Hi. 1) recommend to phone up Heller for assistance on this case 2) using the wakeup profile, can you confirm if the problem remains or not when you skip the warm up of zone # 2? 3) each zone is based on 2 heaters (this is what we have on our 1809e

CFM requirements for Heller 1500 reflow oven exhaust

Electronics Forum | Thu Jul 24 10:49:12 EDT 2008 | slthomas

100 CFM at each exhaust if you're using room air, 25 CFM/ea if you're using nitrogen (according to my manual...never used nitrogen myself) per their specified delivery rates.

Is the condition on your Heller warranty has changed?

Electronics Forum | Fri May 15 17:50:12 EDT 2009 | dynamicsource

Btw, our's was bought in 2001. So basically they said that it is not covered anymore. But we were never told that they changed the condition, until we were claiming for the blower. But in page 143 of the manual, it states, "...terms of this warranty

Heller MK3 edge chain maintenance

Electronics Forum | Thu Feb 13 08:08:41 EST 2014 | cyber_wolf

The manual says to bake the edge chains at 400C to clean them. Is anybody doing this ? I need to take my edge chains to a heat treat facility to clean them ? I don't want to spray oven cleaner on them as they appear to be plated with nickel or so

Hood closing issue in Heller 1809 EXL Reflow

Electronics Forum | Thu May 17 07:45:20 EDT 2018 | vikrantraina

We have Heller Reflow Model 1809 EXL. Today we opened it hood for internal cleaning but now not able to close them. Hood opened more from entry side. We tried to manually force open from exit side & check closing with open/close button, but hood comi

Can someone take a measurement on a HELLER oven please

Electronics Forum | Fri Dec 07 08:49:29 EST 2018 | duke211

I have a similar over and both in and exit should be the same distance apart. You can contact Heller for help. If you have maintenance manual if should tell you how to adjust the timing chain for the lead screws, I am assuming your over have three le

Heller MK5 13 Zone Conveyor Adjust

Electronics Forum | Wed Jun 16 14:07:15 EDT 2021 | oxygensmd

For example, I had the same problem on my Rehm oven. It was in calibration mode. The machine is going to maximum transport width but sensor wasn't reached and the machine stucked in calibration mode. Maybe there are manual mode for transport width a


heller 1900exl manual searches for Companies, Equipment, Machines, Suppliers & Information

Heller Industries Inc.
Heller Industries Inc.

Reflow ovens for automated SMT PCB assembly, specializing in lead free processing and nitrogen reflow. The best convection reflow ovens on the market.

Manufacturer

4 Vreeland Rd.
Florham Park, NJ USA

Phone: 973-377-6800