Partner Websites: 0402 recommended pads size (Page 7 of 55)

PADS Part-Type Name in Batch Create Mode - PCB Libraries Forum - Page 2

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/pads-parttype-name-in-batch-create-mode_topic819_post2931.html

. recommended hole size, but no component mfr. will ever recommend the padstack sizes and that's where you personal rule file automates padstack creation and a simple component body outline automates all drafting items for silkscreen, assembly

PCB Libraries, Inc.

PADS Part-Type Name in Batch Create Mode - PCB Libraries Forum - Page 2

PCB Libraries, Inc. | https://www.pcblibraries.com/forum/pads-parttype-name-in-batch-create-mode_topic819_post2928.html

. recommended hole size, but no component mfr. will ever recommend the padstack sizes and that's where you personal rule file automates padstack creation and a simple component body outline automates all drafting items for silkscreen, assembly

PCB Libraries, Inc.

PADS Part-Type Name in Batch Create Mode - PCB Libraries Forum - Page 2

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/pads-parttype-name-in-batch-create-mode_topic819&OB=DESC_page2.html

. recommended hole size, but no component mfr. will ever recommend the padstack sizes and that's where you personal rule file automates padstack creation and a simple component body outline automates all drafting items for silkscreen, assembly

PCB Libraries, Inc.

Solder Joint Goals - Take II - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic2813&OB=ASC.html

0.55 mm and 0402 Resistor height is 0.40 mm.  We're also using the IPC-7351 3-Tier land pattern system for pad size calculation. The 7351 specification only has one Toe value for each Terminal Lead and it's not based on Height

PCB Libraries, Inc.

Nominal Epad vs Max Epad - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/nominal-epad-vs-max-epad_topic2530.html

: Most component manufacturer's recommended land pattern use the Nominal dimensions for the Thermal Pad size. This is probably the most important reason

PCB Libraries, Inc.

Nominal Epad vs Max Epad - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/nominal-epad-vs-max-epad_topic2530_post10399.html

: Most component manufacturer's recommended land pattern use the Nominal dimensions for the Thermal Pad size. This is probably the most important reason

PCB Libraries, Inc.

Nominal Epad vs Max Epad - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/forum/nominal-epad-vs-max-epad_topic2530_post10400.html

. The old LP Wizard calculated them to max and we still have cells with those size pads. We also still use land patterns per JEDEC OUTLINES

PCB Libraries, Inc.

Nominal Epad vs Max Epad - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/nominal-epad-vs-max-epad_topic2530_post10400.html

. The old LP Wizard calculated them to max and we still have cells with those size pads. We also still use land patterns per JEDEC OUTLINES

PCB Libraries, Inc.

Nominal Epad vs Max Epad - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic2530&OB=DESC.html

. The old LP Wizard calculated them to max and we still have cells with those size pads. We also still use land patterns per JEDEC OUTLINES

PCB Libraries, Inc.

PCB Libraries Forum : Rounding of "Optional Dimensions"

PCB Libraries, Inc. | https://www.pcblibraries.com/forum/RSS_rounding-of-optional-dimensions_topic923.xml

;L and W into L1 and W1 dimensions, then the non-rounded dimensions are remembered.I only noticed this because DipTrace currently will only import PADS components where all the pads are the same size.

PCB Libraries, Inc.


0402 recommended pads size searches for Companies, Equipment, Machines, Suppliers & Information