Electronics Forum | Mon Jun 25 03:52:24 EDT 2012 | awtm
Our Customer had detected tarnished pad on ImAg PCBA and had conducted several SEM-EDX test at the soldermask below some of the chip resistors. High concentration of sulfur was found and it can be significantly reduced after further chemical cleaned
Electronics Forum | Tue Mar 09 18:04:34 EST 2004 | davef
Obviously, if your customer instructs you to use a certain flux type, using THAT flux type is probably a good idea. Responding to your question: Chloride is one of the more detrimental materials found on printed circuit assemblies. Chlorides can com
Electronics Forum | Thu Sep 27 19:52:28 EDT 2001 | davef
All of the discussion of "environmental controls" are a matter of degree, dependent on the requirements of the product that you manufacture. For example: shops assembling under-the-hood products have different requirements than shops making garage d
Electronics Forum | Wed Mar 06 21:16:17 EST 2002 | davef
�What does 5 micrograms of chloride mean to me?� * With SIR testing, you can show no detrimental leakage currents under humid conditions, no corrosion, no metal migration, which are the big factors in figuring out electrochemical reliability. People
Electronics Forum | Sat Sep 25 07:07:02 EDT 1999 | Brian
| I need a memory jog. What is the term for the growth of conductive contamination after a board is in storage or field? | There are several different mechanisms which can cause this. In reality, ionic contamination is the root cause for many of the
Electronics Forum | Mon Apr 01 20:10:24 EST 2002 | davef
Oh. [Howabout if I smack you?] If ahma connectin� wif whut yer sayin�, you: * Don�t like the appearance of the glue slobberin� out from under the component even though there is no apparent glue on solderable surfaces. * Concerned about the hydrosco
Electronics Forum | Mon Jan 08 20:57:52 EST 2001 | Dave F
Are you talking about bare board cleanliness or assembly level cleanliness? Bare board cleanliness is still primarily measured by resistivity of solvent extract (ROSE) using instruments such as Omegameters and Zero Ions. What is considered as "acce
Electronics Forum | Tue Jun 29 18:35:59 EDT 1999 | JohnW
| | Could somebody tell me what means Leaching, ie: "Leaching of terminal end face exposing the ceramic"? | | | Roberto: Leaching, according to the SMTnet Library of Terms: | | Leaching. Dissolution of a metal coating into liquid solder. Nickel ba
Electronics Forum | Thu Jul 01 16:43:52 EDT 1999 | Dave F
| | | Could somebody tell me what means Leaching, ie: "Leaching of terminal end face exposing the ceramic"? | | | | | Roberto: Leaching, according to the SMTnet Library of Terms: | | | | Leaching. Dissolution of a metal coating into liquid solder.
Electronics Forum | Wed Jun 30 11:09:24 EDT 1999 | John Thorup
| | | Could somebody tell me what means Leaching, ie: "Leaching of terminal end face exposing the ceramic"? | | | | | Roberto: Leaching, according to the SMTnet Library of Terms: | | | | Leaching. Dissolution of a metal coating into liquid solder.