Full Site - : ansi/esd (Page 8 of 8)

Facility Humidty controls

Electronics Forum | Mon Jun 17 21:16:19 EDT 2002 | davef

You�re correct about J-001. It�s interesting though, I find no references to controlling temperature and humidity as an element of an electrostatic discharge control program in the following: * ANSI/ESD S20-20 * "ESD Program Management" by Ted Dan

ESD Safe Flooring Systems

Electronics Forum | Mon Feb 10 21:19:51 EST 2003 | MA/NY DDave

Hi I am in favor of the best money can buy tiles, and everything including an ESD officier and training for everyone. Long term less money is spent and ESD protection is kept high continually. Boy do I have stories like the cleaning guys who put on

SMT Lines' Facilities Requirement

Electronics Forum | Thu Sep 29 10:21:11 EDT 2011 | davef

1. Floor loading requirement - The designer of your factory building specified the flooring with a certain floor loading capability. You need to determine that capability. You plan to install machines and equipment. You need to determine the weight o

Solder Iron Tips - Acceptable Temp Tolerance?

Electronics Forum | Sun Sep 02 09:06:42 EDT 2018 | davef

Cold resistance between the tip of the tool and the ground reference, tip current leakage, and tip voltage. per ANSI ESD STM 13.1 J-STD-001 Rev G, Appendix “A” Guidelines for Soldering Tools and Equipment: A-2 BENCHTOP AND HAND SOLDERING SYSTEMS Se

Masking Tape

Electronics Forum | Sat Jul 22 03:27:36 EDT 2023 | shrikant_borkar

hi here are consolidated inputs to you you must validate before establishing your process. ESD-safe Material: Ensure that the masking tape is made of ESD-safe materials that have low triboelectric charge generation. Common materials used in ESD-sa

Re: Humidity control in assembly area.

Electronics Forum | Wed May 03 20:04:21 EDT 2000 | Dave F

Joe: Hey, just hose everyone down with water when your humidity starts to decrease to below 40%. ;-) Actually, that�s how some humidity controllers work, when added to your heating system. Well basically that�s how they work. I�m not tryin� to

Quality assurance

Career Center | Bhiwadi, India | Quality Control

TS 16949:2009 certified internal auditor from bsi. Training on ISO QMS 9001:2008. Training on IPC-A-610 standard Training on visual management, Kaizen & 5 S’’ Well versed about 5S, 8D, 7QC tools, 4M, 3R, 4R, kaizen, kanban, poka yoke, PPAP, SPC, ECN,