Electronics Forum | Wed Oct 18 16:33:26 EDT 2000 | Dave F
Mike: An omega meter has very little to do with ion chromatography. * IPC TM-650, 2.3.25B, Detection and Measurement of Ionizable Surface Contaminants is a process control method that washes boards with an isopropanol / water solution and measures
Electronics Forum | Sun Jul 29 21:23:27 EDT 2001 | nifhail
When carry out the contamination test,do we measure for Chlorides on water soluble and No-clean fluxes? 1) What is the equivalent factor for machines developed to test the board cleanliness, Omega-meter vs Ionograph vs Zero-ion. 2) What values do we
Electronics Forum | Fri Oct 09 23:17:05 EDT 1998 | kallol Chakraborty
| | I need to set a cleanliness limit for our incoming boards. I know that some people use 14-10 microgr. sq. in. But how can I determine what is best for me. | | Can anybody tell me if there's a standard for this. | | Right now we are using an Alph
Electronics Forum | Thu May 14 19:05:02 EDT 1998 | Mike Konrad
Dave, Ionic contamination testers are considered to be a valuable tool to determine the cleanliness of both bare boards and post solder boards. There are some instances when SIR testing is more suitable for determining cleanliness than ionic contamin
Electronics Forum | Tue Oct 07 14:23:37 EDT 2003 | Adam
The Omegameter (or Ionograph) detect contamination by measuring the conductivity of the solution used to extract the board. This conductivity number reflects the sum of all of the ionics in the extraction solution. Unfortunately, we can't sort out th
Electronics Forum | Thu Jan 05 20:34:32 EST 2006 | davef
We agree. It sounds like your tester is possessed. If it starts vomiting pea soup, throw it away. Otherwise: * Follow Pete's suggestion by calling Alphametals [or whatever they call themselves nowadays] * Contact analytical laboratories and ask th
Electronics Forum | Sun Feb 26 21:48:28 EST 2006 | Mike Konrad
Hi GS, Just a clarification� No-clean does NOT equal no ions. It equals less ions (at best). Automatic R.O.S.E (Resistivity Of Solvent Extract) testers are commonly used to detect ionic contamination from no-clean applications. Your comment rega
Electronics Forum | Thu Sep 11 18:44:31 EDT 2008 | smt_guy
We have an Ionic Contamination Testing system but short of having a monitoring record for the chemical concentration. What we have is a monthly maintenance check of the concentration and annual check and calibration of the chemicals. We seldom use th
Electronics Forum | Thu Oct 17 17:29:46 EDT 2013 | lordofpiggies
Hello. We are building a CCA which has a silicone-based adhesive whose purpose is to bond the bottoms of multiple LED displays to heat sinks. Our customer wants the CCA to be tested for ionic residues per J-STD-001, but we are hesitant to test the
Electronics Forum | Tue Apr 17 09:38:04 EDT 2001 | CAL
With some help from our good Friends at Agilent Technologies our RF Lab includes testing up to 100GHz. Equipment includes Vector network analyzer, signal analyzer, dual channel power meter, noise filter meter, advanced impedance analyzer (including