MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 09:40:14 EDT 2014 | rgduval

I'm surprised MyData is pushing the service call. They're usually pretty good at walking you through some troubleshooting steps before going straight to the service call. So, the failure sounds like an encoder failure; the encoders are attached to

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:22:53 EDT 2014 | rgduval

Hi, Rebecca, Hmm...two x motors? I'm a couple of years removed from MyData's, but, I don't remember two x-motors. Might be something in the My12's that I didn't see in my older My9 (and certainly not in my TP9). As to the small board...unfortun

MYData placement variations

Electronics Forum | Wed Feb 28 07:30:26 EST 2007 | cyber_wolf

We recently scrapped our TP9-2U because of an issue similar to this. The X-axis would overshoot the pick and place positions. This particular machine(2U)only has 1 X motor. The UFP's and the MY machines have a small fine positioning motor that is on

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Mon Nov 25 10:57:31 EST 2019 | rgduval

You should be able to see the counts in the service screen for the motors while testing them...that's usually the easiest way to see if they're functioning...at least the encoders. In some of the older systems, the drive motors were all the same, an

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Wed Jul 26 16:08:29 EDT 2006 | ev

My focus has moved to the X motor itself. The one common factor in this paricular problem has been the time of year. The day was a particularly hot day with high humidity. Even though there is a "Xfan" connection on the PIAB board I do not believe th

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:33:32 EDT 2014 | cflames17

It could very well be the Safety Relay located inside the ELMO PSU (Bottom left in computer cabinet). I just had the same problems on 2 MY9's within 2 months apart. the Part cost around $700.00 from Mydata (Now Mycronic). These fail commonly with old

Mydata (TP9-2U) problem

Electronics Forum | Mon May 13 10:08:44 EDT 2013 | rgduval

I've heard that MyData is no longer supporting the TP's, so, getting a new motor might be a difficult proposition. If you can find the motor manuf/part number on the motor itself, you can likely find it on line somewhere...Google the p/n should do i

MyData Y wagon shudder

Electronics Forum | Fri Mar 11 09:42:50 EST 2005 | cyber_wolf

If you are not getting repeatable transducer readings then some possiblities are : 1. Transducer is bad 2. Motor is bad 3. Y power booster Also, I can't remember if the Y motor has a flex coupling on it or not. If it does, check that out. Also, w

MYDATA My9 Theta error

Electronics Forum | Tue Nov 13 11:41:23 EST 2012 | dontfeedphils

I can't remember what motor control cards in the machine are interchangeable, but if the controller card for the theta axis is a common control card then you can swap out the one currently controlling the theta axis with a different axis and see if t

MYDATA My9 Theta error

Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc

Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu


fried motor mydata searches for Companies, Equipment, Machines, Suppliers & Information

used smt parts china

Reflow Soldering 101 Training Course
Conductive Adhesive & Non-Conductive Adhesive Dispensing

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
High Throughput Reflow Oven

World's Best Reflow Oven Customizable for Unique Applications