Full Site - : motor timeout mydata (Page 9 of 20)

Mydata A12 tool tip damage

Electronics Forum | Thu Jul 19 08:33:37 EDT 2007 | allgood

Ok I can get into the service program - under Motors there is only a single X motor listed. And what test can you do - seems that I can only display ranges and settings? No test as such?

Mydata M12 issue

Electronics Forum | Tue Oct 27 12:23:44 EDT 2009 | cyber_wolf

One thing a lot of people don't know is that the small X motor on MY machines have carbon brushes in them. If you do not replace the brushes before they wear out it trashes the motor.

MYDATA F-MOT-MOVE X/245 Motor drive inhibited

Electronics Forum | Thu Oct 11 06:09:50 EDT 2018 | mk15

hello, Does anyone know about the error F-MOT-MOVE X/245 Motor drive inhibited. The machine hardware initiation ready and approximately an hour later, you will see an error. Thanks

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Mon Nov 25 02:15:07 EST 2019 | mk15

it is possible to test x belt motor and x wagon motor.

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Thu Sep 04 09:40:14 EDT 2014 | rgduval

I'm surprised MyData is pushing the service call. They're usually pretty good at walking you through some troubleshooting steps before going straight to the service call. So, the failure sounds like an encoder failure; the encoders are attached to

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:22:53 EDT 2014 | rgduval

Hi, Rebecca, Hmm...two x motors? I'm a couple of years removed from MyData's, but, I don't remember two x-motors. Might be something in the My12's that I didn't see in my older My9 (and certainly not in my TP9). As to the small board...unfortun

MYData placement variations

Electronics Forum | Wed Feb 28 07:30:26 EST 2007 | cyber_wolf

We recently scrapped our TP9-2U because of an issue similar to this. The X-axis would overshoot the pick and place positions. This particular machine(2U)only has 1 X motor. The UFP's and the MY machines have a small fine positioning motor that is on

MYDATA MY15E F-MOT-MOVE X/250 problem

Electronics Forum | Mon Nov 25 10:57:31 EST 2019 | rgduval

You should be able to see the counts in the service screen for the motors while testing them...that's usually the easiest way to see if they're functioning...at least the encoders. In some of the older systems, the drive motors were all the same, an

Mydata TP11 UFP hardware initiation failure

Electronics Forum | Wed Jul 26 16:08:29 EDT 2006 | ev

My focus has moved to the X motor itself. The one common factor in this paricular problem has been the time of year. The day was a particularly hot day with high humidity. Even though there is a "Xfan" connection on the PIAB board I do not believe th

MY12 F-MOT-MSETDYN x/12: Position Counter Dead

Electronics Forum | Fri Sep 05 09:33:32 EDT 2014 | cflames17

It could very well be the Safety Relay located inside the ELMO PSU (Bottom left in computer cabinet). I just had the same problems on 2 MY9's within 2 months apart. the Part cost around $700.00 from Mydata (Now Mycronic). These fail commonly with old


motor timeout mydata searches for Companies, Equipment, Machines, Suppliers & Information

Electronics Equipment Consignment

High Precision Fluid Dispensers
2024 Eptac IPC Certification Training Schedule

Best Reflow Oven
Circuit Board, PCB Assembly & electronics manufacturing service provider

Training online, at your facility, or at one of our worldwide training centers"
design with ease with Win Source obselete parts and supplies

Training online, at your facility, or at one of our worldwide training centers"