Full Site - : mydata tp-9 (Page 9 of 27)

Mydata M100 Series ?

Electronics Forum | Tue Aug 19 10:29:28 EDT 2008 | dyoungquist

Looked like a sweet machine at the APEX show but I have not used one. Sure wish I could talk my boss into getting one before our old Mydata TP9 machine dies.

Looking for a Mydata TP-11

Electronics Forum | Tue May 28 05:41:48 EDT 2013 | Adrian

HI Sr Tech, I have a mydata TP9 for sale as spare parts machine. I think one of the board is defective. No feeders. Location: Malaysia. If interested , please send me a email: adrianchongyk@yahoo.com thanks Adrian

My-Data TP9-UFP info please!!!

Electronics Forum | Fri Apr 27 11:47:28 EDT 2007 | BKG

We are looking at obtaining a TP9-UFP and I have never worked on mydata before. Most of my experience is on Philips and QUAD. Opinions on practicallity for low volume high mix application? What is the actual CPH? I see it is rated at 6000cph, but in

Need help on Mydata TP9-2U

Electronics Forum | Tue Nov 15 08:17:05 EST 2005 | cyber_wolf

What are you trying to calibrate? I think you mis-typed...there is no W-wagon. I think you meant X-wagon camera. I have never seen one of these go out of cal. Why do you think it needs calibrated ?

Mydata TP9-2 Help

Electronics Forum | Mon Aug 06 18:58:12 EDT 2007 | edruppert

This message indicates that the Peak to Peak voltage for the x axis motor encoder is too low. Possible cable/encoder or MOT1 board problem. Machine will either exhibit this during intialization or while running. Diagnostics in service routine may he

reviews on pick and place machines

Electronics Forum | Mon Nov 12 10:28:22 EST 2007 | chrisruizuci

i just wanted to get others input on the MyData TP9 and Philips Topaz. Any advise at all would be helpfull.

MyData TP9-UFP Networking

Electronics Forum | Wed Dec 07 13:35:11 EST 2011 | cyber_wolf

Just curious, Why do you need to attach one machine to a PC ? Throw the data on a floppy and call it a day.

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 13:41:36 EDT 2013 | cyber_wolf

MOVFI is a theta error there are about 10 things that can cause it. Start with making sure you do not have an acceleration set to lowest while the others are at high or highest in the package data. Next look at ribbon cables...

Mydata (TP9-2U) problem

Electronics Forum | Tue May 07 14:33:57 EDT 2013 | cyber_wolf

The "lowest" acceleration is probably causing your problem. Switch it to the next fastest setting and see what happens

MyData TP9 dead?

Electronics Forum | Thu Feb 06 14:01:55 EST 2014 | rgduval

1. Fuse 2. Power Supply 3. Power Distribution card 4. Booster Start by checking all of the fuses on the front of the power supply (accessed by removing the front cover of the machine). Then, check all of the fuses on the first card in the MOT bay.


mydata tp-9 searches for Companies, Equipment, Machines, Suppliers & Information

Equipment Auction - Eagle Comtronics: Low-Use Electronic Assembly & Machining Facility 2019 Europlacer iineo + Placement Machine  Test & Inspection: Agilent | Tektronix | Mantis Machine Shop: Haas VF3 | Haas SL-20 | Mult. Lathes

Easily dispense fine pitch components with ±25µm positioning accuracy.
PCB Handling Machine with CE

Best Reflow Oven
Fluid Dispensing, Staking, TIM, Solder Paste

Training online, at your facility, or at one of our worldwide training centers"


Training online, at your facility, or at one of our worldwide training centers"