Electronics Forum | Sat Oct 10 11:24:50 EDT 2015 | cusackmusic
I've been running Quads for over 10 years, and I love them. I've had almost every model, from the 100, to our current IVCs, and QSP2. We are getting busier, and I'm thinking about upgrading. I have TONS of feeders, so the simple solution would be t
Electronics Forum | Mon Mar 21 22:09:28 EST 2005 | dlkearns1
Did you get your answer? From all the reading I've done since your posting, does this issue happen when running a "specific" program or any/all programs ? Just a thought, as MOD codes can be tricky. Also check the thru-holes on that backplain conn th
Electronics Forum | Mon Jan 21 06:04:12 EST 2013 | bobpan
Some things to try.....keep in mind it has been over 10 years since i programmed one of those machines. 1. Tep Vision is what you should be using. I think it was called tep vpass in older software. 2. Maybe try goto 0 instead of goto 1. 3. Make sure
Electronics Forum | Mon Jan 21 09:54:22 EST 2013 | ngineer
Bobpan and all future people with this problem, GOTO 0 Fixed the problem. It also counts boards now. I never knew why it didn't count the boards run. Haven't looked in the manuals, but I would bet that it shows this plainly. This makes sense,
Electronics Forum | Tue May 07 14:47:31 EDT 2013 | ngineer
Z axis seems to move as it should, the flag that goes through the C shaped sensor is not broken. I have gotten it to stay on everytime i start it up now (I did NOT change anything, just unplugged it for awhile, then plugged it back in an flipped the
Electronics Forum | Wed Aug 10 20:30:49 EDT 2005 | slthomas
I've got a new board (actually a new panel...a 4 up, with one row rotated, where it was a 2 up panel with no rotation before) that runs fine on the IVc but not on the IIIc. I've used the same reference points for the image rotation (fiducials) on bot
Electronics Forum | Thu Jan 16 18:14:35 EST 2003 | jonfox
You can still get support. I was in that deal before Tyco decided they didn't need Multitronics field engineers playing with Quads. Anyway, most of the original Quad personnel are stil running service. Based by region, in the West or Central US, c
Electronics Forum | Tue Nov 10 09:45:52 EST 1998 | Scott McKee
| We are currently in the process of purchasing a new low volume SMT line. Based on our research, Quad and Mydata seems to best fit our applications. Has anyone used both equipment and experience the pro and cons of each machine? Thanks in advance fo
Electronics Forum | Sun Nov 06 16:10:25 EST 2016 | teslalab2
Hi! I have a Quad IVc pick and place that runs dos. The GUI computer is a compaq prolinea 4/33s. The hard drive went stupid mode and now wont respond. I have all of the data backed up. I tried transferring the files to a fairly modern hard drive (20g
Electronics Forum | Thu Aug 16 07:40:27 EDT 2012 | bobpan
Here are a couple of things to look at. 1. Watch the machine run....and if it misses a part....make sure it doesnt blow out the next part being presented. Sometimes the air pressure is too high and the vacuum verify will blow the part out of the poc