Full Site - : chamber (Page 10 of 94)

What causes temperature humidity chamber to alarm?

Technical Library | 2019-12-12 02:43:44.0

Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.

Symor Instrument Equipment Co.,Ltd

The climatic test chamber after-sale service

Technical Library | 2019-06-18 03:23:42.0

After-sale service Climatest Symor® strictly controls every production procedure,our main after-sale service procedure is as follow: 1) Email Climatest Symor® about the fault description(Pictures or video is preferred) 2) Within 1 working days, Climatest Symor® gives feedback or solution (If Climatest Symor® needs customer to take pictures about some parts of the machine, customer should cooperate accordingly to settle issues. 3) If checked that some parts(except glass nozzle) is possible broken by non-artificial reason, If necessary, customer deliver the broken part to Climatest Symor®, later Climatest Symor® send the repaired part or new part to customer. If unnecessary, Climatest Symor® will make delivery for the new part to customer directly. Remark:During warranty, Climatest Symor® is responsible for delivery fees both ways and parts fees.After warranty, Customer is responsible for the delivery fees both ways,Climatest Symor® will provide the parts to customer by cost price.

Symor Instrument Equipment Co.,Ltd

Maintenance and operation of walk-in temperature humidity test chamber

Technical Library | 2019-11-17 22:46:45.0

Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers

Symor Instrument Equipment Co.,Ltd

Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

Factors determine the price of temperature humidity test chamber

Technical Library | 2019-12-16 22:20:55.0

When we were children,our parents always warn us "Do comparison shopping before you buy",why they say like this?this is a very simple truth, for the first deal,we are always cautious, through continuous comparison in order to find out the best quality, service, after-sale and price. This apply to any industry,there are many manufacturers of environmental test equipment. When some customers inquire a temeprature humidity test chamber, they will find a very common problem. Why is the price of the same equipment quoted by the two manufacturers very different? 1, the chamber body process,which effects the exterior case quality,this price has a gap. 2, the components, esp.components of the refrigeration system, is the core value of the temperature humidity test chamber. 3, even if the body and refrigeration components are the same, some prices are different, that is the manufacturer technical level. 4, regional issues, Wuxi,Changzhou, Dongguan, these brands need to know more. 5. after-sales, a powerful manufacturer often with a sound after-sales service dept.. The above are both technical and service, as well as the delivery cost of goods to the local and overseas are different.

Symor Instrument Equipment Co.,Ltd

AI SI LI (CHINA) TEST EQUIPMENT CO., LTD

Industry Directory | Manufacturer

ASLi main products: Temperature (humidity) chamber, Thermal Shock Test Chamber, Sand and Dust Tester , Rain Spray Tester, UV Chamber, Ozone Chamber, Xenon Climate Chamber , Salt Spray Corrosion Chamber, High Temperature (Vacuum )

Guangdong ALI Testing Equipment Co,.Ltd

Industry Directory | Manufacturer

environmental test chamber manufacturers and vibration test system suppliers. Including climate test chamber, thermal shock test chamber, stability test chamber, ESS chamber, walk-in test chamber, altitude test chamber,

DEK DEK CHAMBER USC VACUUM 610MM 193823

DEK DEK CHAMBER USC VACUUM 610MM 193823

Parts & Supplies | Assembly Accessories

We can bring you the following benefits. 1. Save costs 2. MOQ:1 pc 3. You can find the SMT parts you want 4. Fast delivery-- receive the goods in about 7 days 5. Sincere one-to-one professional service 6. Quick response after-sales service Ple

Ruihua Electronic Co.,Ltd

Thermotron SM-16-8200 Humidity Chamber

Thermotron SM-16-8200 Humidity Chamber

Used SMT Equipment | In-Circuit Testers

Thermotron Model SM-16-8200 Humidity Chamber, Auction Item: Major Auction July 20th Multiple Chambers Available:

X-Line Asset Management

Thermotron SE-Series Chamber

Used SMT Equipment | General Purpose Equipment

SE-Series Thermotron Chamber. Ideally SE-600. Humidity not essential. Any condition considered.

Realtime Technologies


chamber searches for Companies, Equipment, Machines, Suppliers & Information