Electronics Forum | Fri Mar 11 09:42:50 EST 2005 | cyber_wolf
If you are not getting repeatable transducer readings then some possiblities are : 1. Transducer is bad 2. Motor is bad 3. Y power booster Also, I can't remember if the Y motor has a flex coupling on it or not. If it does, check that out. Also, w
Electronics Forum | Tue Nov 13 11:41:23 EST 2012 | dontfeedphils
I can't remember what motor control cards in the machine are interchangeable, but if the controller card for the theta axis is a common control card then you can swap out the one currently controlling the theta axis with a different axis and see if t
Electronics Forum | Tue Nov 20 15:03:37 EST 2012 | jaimebc
Bruce, Since we had spares, I replaced the X wagon cables, XFMB cable, nothing. FFX Cable, nothing. Swapped mot cards, nothing. Vaccum seal, nothing.At this point I truly believe the problem is either on the theta encoder or the theta motor. Unfortu
Electronics Forum | Thu Jul 18 00:08:31 EDT 2019 | mk15
hank you for the tips. MOT boards have already changed. The sensor on the conveyor responds. In service mode, the WIDTH MOTOR - OK, HOLD MOTOR - OK, SET CONVEYOR - OK, only error TRANSPORT - F-MOT-MSETDYN conveyor transport / 1250: amplifier DC-link
Electronics Forum | Mon Oct 25 11:20:52 EDT 2021 | bk
The 245 error is with your x belt motor not the x wagon motor. double check all the fuses on the back of the machine where your power comes in there should be 3 of them. if you haven't changed your blue cables in a while I would change those out. you
Electronics Forum | Thu Mar 26 08:51:40 EDT 2009 | avalancher
Hi Sr. First suggestion is to call Mydata's phone support. With that said... Here is some ideas of what you could check: 1. Do you have power at the XWB board connector going to the motor (xxwm connector)? 2. Do you have power coming through the bl
Electronics Forum | Wed Mar 25 14:55:17 EDT 2009 | cyber_wolf
The small x motor quit working.It seems that there is no voltage going to the motor. Here is what I have done so far: *Verified that the motor is good. *Check pico fuses on the backplane *Verify voltages on backplane and on big booster. *Swap mot ca
Electronics Forum | Mon Apr 20 08:32:28 EDT 2009 | cyber_wolf
I actually did replace the cable from the comp box to the X-boards. The original small x-motor was indeed bad. I verified this by taking it to my working machine and trying to pulse it when it was in my hand. (the mot boards were loaded). Then I to
Electronics Forum | Tue Jun 01 08:42:08 EDT 2010 | rgduval
I'm randomly having some motor move errors, as well. If you swap your MOT board, and the problem continues, you're down to a couple of problems. Could be that the motor is getting ready to die on you. Could be an encoder problem. Or, could be som
Electronics Forum | Fri Jul 10 19:53:31 EDT 2015 | tamazula
make sure noting stock in the X ,and motor brake > work usually machine supply 24V to motor brake > wire for release brake then move until hit the > end stopper for init motor if brake keep on > that will the error message > > i got it ofte