Geiger Muller Counter Tube High Voltage Power Supply
Company Information:
Name: |
Geiger Muller Counter Tube High Voltage Power Supply |
Offered by: |
|
Geiger Muller Counter Tube High Voltage Power Supply Description:
Product Name MG
Power(W) 0.5W
Output Voltage(KV) ,0.1,0.125,0.2,0.25,0.3,0.4,0.5,0.6,0.8,1,1.1,1.25,
ISO9000:2008 certified precision module .The MG Series is ideal for OEM applications requiring a competitively priced, precision high voltage module.
Low noise:5mV
High stability:0.001%
Line Regulation:0.001%
Load Regulation:0.001%
Temperature Coefficient:Better than 15ppm/°C.
Compact and light weight
Both external VR or voltage control
APPLICATIONS
High voltage testing
PMT,MCP,radiation counter
Electron Beam/Ion Beam
MAss spectrometry
Electrostatic chuck(ESC)
Photomultiplier Tubes
Scintillators
Electron Guns
Ion Guns
Nuclear Instruments
Electrostatic lenses
Spectroscopy
Microchannel Plates
SPECIFICATIONS
Input Voltage:
12Vdc±1VDC,100mA TYP. Option:-15:15Vdc±1VDC , 0.1A maximum , -24:24Vdc±1VDC , 0.1A maximum ,
Nominal Voltage Range:
7Vdc to 15Vdc.
Input Current: (typical)
Disabled: 30mA
No load: 90mA
Full load:
250mA TYP
Efficiency:
80-85%, typical
Voltage Re gulation:
Line: <0.001%
Load: <0.001%
Current Re gulation:
Line: <0.001%
Load: <0.001%
Output Voltage:
Continuously adjustable over entire output range. Available
in either positive or negative output polarity. See table for
voltage ranges.
Output Voltage Control: Controlled by either:
1) External potentiometer 100k (set internal pot. to MGx.)
2) Remote differential voltage programming (0 to +5V gives
0 to full output).
Accuracy:
2% on all programming and monitoring,
Temperature Coefficient: (typical)
Optional: 15ppm/°C (T Option)
Environmental:
Temperature Range:
Operating: -40°C to 65°C case temperature
Storage: -55°C to 85°C, non operational
Humidity:
10% to 90%, non-condensing.
Cooling:
Convection cooled, typical. 60 watt units operating at full power
might require additional cooling to maintain case temperature
below 65°C. Methods may include: forced air cooling, use of
heat sink or metal case, etc. It is the user’s responsibility to
maintain the case temperature below 65°C. Damage to the
power supply due to inadequate cooling is considered misuse
and repairs will not be covered under warranty.
Dimensions:
50.8x25.4x12.7
Weight:
30g
Geiger Muller Counter Tube High Voltage Power Supply was added in Feb 2015
Geiger Muller Counter Tube High Voltage Power Supply has been viewed 123 times