AMAT 0090-76133 SBC BOARD
Company Information:
Name: |
AMAT 0090-76133 SBC BOARD |
Category: |
|
Offered by: |
|
AMAT 0090-76133 SBC BOARD Description:
Contact: Nancy Lin
Email:info@amikon.cn
Skype:onlywnn_1
Telegram:+8618020776786
Mobile(Whatsapp): (+86)-18020776786
QQ :2851195456
Control Systems (DCS, PLC/SPS, CNC)
- Panel Controllers
- HMI and Display Panels
- Industrial PC’s
- Drives ( Frequency Inverter and Servo)
- Motors
- Power Supplies
Amikon adhering to the enterprise concept of excellence, whether it is industrial automation parts, services or delivery efficiency, we are committed to do better.
We deliver a variety of parts.
AMAT 0090-76133 SBC BOARD
AMAT 0090-76133 SBC BOARD
AMAT 0090-76133 SBC BOARD
Background Window
A CPU self-test is performed in this window. Included in this self-test is a verification of the
checksum for the 90-70 CPU operating system software.
The Background Window time defaults to 0 milliseconds. A different value can be configured and
stored to the PLC, or it can be changed online using your programming software.
Time and execution of the Background Window can also be dynamically controlled from the user
program using Service Request function #5. This allows background functions to be skipped during
certain time-critical sweeps.
Window Modes
The previous sections have described the phases of a typical PLC sweep. The Programmer
Window, System Communications Window, and Background Window phases of the PLC sweep
can be run in various modes, based on the PLC Sweep mode. (PLC sweep modes are described in
detail in section 4.) The following three window modes are available:
Run-toCompletion
In Run-to-Completion mode, all requests made when the window has started
are serviced. When all pending requests in the given window have completed,
the PLC will transition to the next phase of the sweep.
Constant In Constant Window mode, the total amount of time that the Programmer
Communications Window, System Communications Window, and
Background Window run is fixed. If the time expires while in the middle of
servicing a request, these windows are closed, and communications will be
resumed the next sweep. If no requests are pending in this window, the PLC
will cycle through these windows the specified amount of time polling for
further requests. If any window is put in constant window mode, all will be in
constant window mode.
Limited In Limited mode, the maximum time that the window runs is fixed. If time
expires while in the middle of servicing a request, the window is closed, and
communications will be resumed the next time that the given window is run. If
no requests are pending in this window, the PLC will proceed to the next phase
of the sweep.
CATC 2500
FX-128MR
GV-U6E-NK
LLS5008
GMMDSDINT-1T2
DMC50ME200D0M001
MPXL502
CIMR-V7AA21P5
CRS1010
UFC-2050A
CURT-1261-0
858-8148-006 J A5170
IFC-7300-001
305-04043B-010L
AURORA 2 TEST SET 30 DAY
VFSX-2022UP1
MIO-PS120 W/
MIO-IDC-32-100 W/
MIO-ODC-32-200 W/ BASE 5
CONTROLLER 000134
PWR_MTH3 4S013-494
CPU-211N
CX1304C
6ES7318-2AJ00-0AB0
LDP500P-14
E82EV751_2C200
IV-LF-COMBO-02
Masterflex 7520-47
BEAM 300mm 0010-15708
SGDM-04ADA
2179A-24801
SC-AT-4M
AMAT 0090-76133 SBC BOARD was added in Dec 2017
AMAT 0090-76133 SBC BOARD has been viewed 295 times
20 More Products from Amikon Automation Equipment Co., LTD :