Honeywell 10101/2/1 Digital Input Module
Company Information:
Name: |
Honeywell 10101/2/1 Digital Input Module |
Category: |
|
Offered by: |
|
Honeywell 10101/2/1 Digital Input Module Description:
Sales Manager: Sandy Lin
Email: unity@mvme.cn
Skype:onlywnn_1
Mobile(Whatsapp): (+86)-18020776786
yuehang:
Shipping Term : TNT,DHL,FEDEX,ETC
Payment Term : T/T
Warranty: 12 month
yuehang supply: New+original+factory sealed+high quality
Service: quotation will be sent in 9 hours
Skype + whatsapp + mobile = 24 hours /day Oneline.
Application field
Company products are widely used in CNC machinery and metallurgy, oil and
gas,petrochemical, chemical, paper printing, textile printing and dyeing, machinery, electronic
manufacturing, automobile manufacturing, tobacco, plastic machinery, electric power,water
conservancy, water treatment / environmental protection, municipal engineering,boiler
heating, energy, power transmission and distribution.
Honeywell 10101/2/1 Digital Input Module
Honeywell 10101/2/1 Digital Input Module
Honeywell 10101/2/1 Digital Input Module
Operands
During man-machine communication the display and modification of operands play a large role. For this reason an
overview of all of the operands of the PLC is given here.
2.2.1 Operands of 07 KT 94
2.2.1.1 Available variables and constants
Inputs
E 00,00...E 61,15 : Digital inputs, CS31 remote module
E 62,00...E 63,15 : Digital inputs of the basic unit 07 KT 94
E 64,00...E 64,07 : Digital inputs of the basic unit 07 KT 94 (formed of EW 06,00...EW 6,07)
E 65,00...E 99,15 : reserved
E 100,00...E 163,15 : reserved
E 200,00...E 263,15 : reserved
EW 00,00...EW 05,15 : Analog inputs, CS31 remote module
EW 06,00...EW 06,07 : Analog inputs of the basic unit 07 KT 94
EW 07,00...EW 07,07 : reserved
EW 07,08...EW 07,14 : Reading of the real time clock
EW 07,15 : Status for CS31 system bus
EW 08,00...EW 15,15 : Analog inputs CS31 remote module
EW 16,00...EW 34,15 : reserved
EW 100,00...EW 107,15 : reserved
EW 200,00...EW 207,15 : reserved
Outputs
A 00,00...A 61,15 : Digital outputs, CS31 remote module
A 62,00...A 63,07 : Digital outputs of the basic unit 07 KT 94
A 62,00 : High-speed counter, after activation direct output of the "zero crossing"
A 65,00...A 99,15 : reserved
A 100,00...A 163,15 : reserved
A 200,00...A 263,15 : reserved
AW 00,00...AW 05,15 : Analog outputs, CS31 remote module
AW 06,00...AW 06,03 : Analog outputs of the basic unit 07 KT 94
AW 07,00...AW 07,15 : reserved
AW 08,00...AW 15,15 : Analog outputs CS31 remote module
AW 16,00...AW 34,15 : reserved
AW 100,00...AW 107,15 : reserved
AW 200,00...AW 207,15 : reserved
Internal Operands
M 00,00...M 254,15 : Binary flags
M 255,00 : Oscillator approx. 2 Hz
M 255,01 : Oscillator approx. 1 Hz
M 255,02 : Oscillator approx. 0,5 Hz
M 255,03 : Oscillator with period interval of approx. 1 minute
M 255,04 : Oscillator approx. 1/8 Hz
M 255,05 : Oscillator approx. 4 Hz
M 255,06 : Oscillator approx. 8 Hz
M 255,10 : Sum error message
M 255,11 : Error message FK1
M 255,12 : Error message FK2
M 255,13 : Error message FK3
M 255,14 : Error message FK4
M 255,15 : Recognition "new start"
M 256,00...M 279,15 : System flags / reserved
M 280,00...M 511,15 : Binary flags
S 00,00...S 255,15 : Steps
K 00,00...K 00,01 : Binary constants
MW 00,00...MW 253,15 : Word flags
MW 254,00...MW 255,15 : Error message
MW 256,00...MW 259,15 : System flags / reserved
MW 260,00...MW 511,15 : User area
KW 01,00...KW 79,15 : Word constants
MD 00,00...MD 63,15 : Double word flags
KD 00,01...KD 23,15 : Double word constants
Time values for time functions
KD yy,xx : Time values for time functions such as ESV, ASV etc. are configured as double word constant or as
MD yy,xx : double word flags. Only integer multiples of 1 ms are permitted.
2.2.1.2 Direct constants
Direct constants are only permitted with function blocks on certain inputs. Where this is the case it is explained in
the description of the function modules.
# -32768...+32767
#H 0000...FFFF
2.2.1.3 Labels
Labels serve as jump targets for forward jumps and consecutive number blocks.
MA 0...999
2.2.1.4 System constants
Setting the operating modes
The constants KW 00,00...KW 00,15 are reserved as system constants. Even the constants KW 00,13...KW 00,15
which are not used yet may under no circumstances be used for other purposes.
KW 00,00 : Setting the PLC operating mode (stand-alone PLC, master PLC, slave PLC)
KW 00,01 : Initialization: bit flag area
KW 00,02 : Initialization: word flag area
KW 00,03 : Initialization: double word flag area
KW 00,04 : Initialization: step chain flag area
KW 00,05 : Initialization: historical values
KW 00,06 : Application modes of the serial interface COM 1
KW 00,07 : PLC reaction to class 3 errors
KW 00,08 : PLC reaction to an overload/short-circuit at the transistor outputs
KW 00,09 : Minimum number of remote modules integrated in the CS31 system bus cycle
KW 00,10 : Size of the transmitting area of the slave PLC
KW 00,11 : Size of the receiving area of the slave PLC
KW 00,12 : Automatic warm start after an FK2 error
KW 00,15 : Deactivate oscillators at M 255,00...M 255,06
KW 85,00...KW 85,03 : Configuration of the signal delay of digital inputs
KW 85,02 : Configuration of the operating modes of the high-speed counter
KW 86,00...KW 86,07 : Configuration of the analog inputs
KW 88,00...KW 88,03 : Configuration of the analog outputs
Setting the cycle time
KD 00,00 : This constant serves as the specification of the cycle time for the PLC program. The cycle time
is given in milliseconds. Only integer multiples of 1 ms are permitted.
GAI TRONICS 758-001 AMPLIFIER ENCLOSURE W/ TYPE 751
DANAHER CONTROLS NS0512ZK14R SPARE WHEEL 2.000" 750-246-108R
BALDOR VECP3582T
DAYTON 4Z290C SPEED REDUCER 10.1 RATIO J855/C96F
MASONEILAN 622110001-999
BROOK CROMPTON 5925100WA-23 ELECTRIC MOTOR FRAME TYPE W-DA100L, 4.0HP
CLEVELAND GEAR 1-7/8CA1 WORM GEAR REDUCER 5-1 RATIO
HIRSCHMANN MM3-4TX1-RT
TAYLOR 125S1462 INPUT BOARD AC 1820374
RELIANCE ELECTRIC 0-51821 PC
VERSA TZI-2601-155
FLOWSERVE 2221492 PLUG: BALANCE VALVE 22214S
Vernitron Corp. VTX37-618
B&R ECPA81-01 OUTPUT MODULE REV. 00.00
B&R ECPA81-01 OUTPUT MODULE REV. 01.00
Eurotherm Corporation EMM/MAS/M0300D/ENG/STD-REC
NAMCO EE230-32320
CUTLER HAMMER FD3015L
BAUMER GA211.110B106 ENCODER 081210-11
CLEVLAND MOTION CONTROLS 4104DC000SD0ACJ007 PM
RELIANCE ELECTRIC 602909-68AE
ELKHART IN-LINE FOAM
BAUER BS06-44V/D08MA4W/C1-SP
SANDPIPER S07B1P2PPNS000
TOCCO D-14745
ACCURAY 061595-003
PARKER D3W4CNYC56
ANDERSON GREENWOOD M4AVIC-TR68
AMCI H25S-FS-HFL ROTARY TRANSDUCER H25SFSHFL
WOODMAN D-15300-A
ALLEN BRADLEY 509-AJB
VEGA 589-10EX VEGATOR 535EX
HYSTER 7697 REV. L 3-WAY
SIEMENS 43CP32A
SIEMENS 3RB2143-4EB0
SIEMENS P1C42ML250CTS
MITSUBISHI AY-23 OUTPUT MODULE AY23
PARKER D1VW004CNYGF56
MTS TEMPOSONICS GPS0600UFD12ND1
DET-TRONICS 003240-201 UV
EATON CUTLER HAMMER 8170A-6501 SERIES 70
STAEFA CONTROLS SYSTEMS FK-V32 MODULE 091-56000
ALLEN BRADLEY 855EE-B24Y3Y8Y4P1
HUNT P135-1104
GENERAL ELECTRIC Q366A773G13
CONVERTER CONCEPTS VT50-341-10/XX
WOODMAN D-14689 PC
Honeywell 10101/2/1 Digital Input Module was added in Jan 2018