Siemens Moore 16147-51-2 ACM Transition Board Control Module
Company Information:
Name: |
Siemens Moore 16147-51-2 ACM Transition Board Control Module |
Category: |
|
Offered by: |
|
Siemens Moore 16147-51-2 ACM Transition Board Control Module Description:
Sales Manager: Sandy Lin
Email: unity@mvme.cn
Skype:onlywnn_1
Mobile(Whatsapp): (+86)-18020776786
yuehang:
Shipping Term : TNT,DHL,FEDEX,ETC
Payment Term : T/T
Warranty: 12 month
yuehang supply: New+original+factory sealed+high quality
Service: quotation will be sent in 9 hours
Skype + whatsapp + mobile = 24 hours /day Oneline.
Application field
Company products are widely used in CNC machinery and metallurgy, oil and
gas,petrochemical, chemical, paper printing, textile printing and dyeing, machinery, electronic
manufacturing, automobile manufacturing, tobacco, plastic machinery, electric power,water
conservancy, water treatment / environmental protection, municipal engineering,boiler
heating, energy, power transmission and distribution.
Siemens Moore 16147-51-2 ACM Transition Board Control Module
Siemens Moore 16147-51-2 ACM Transition Board Control Module
Siemens Moore 16147-51-2 ACM Transition Board Control Module
Ground the Drive and Enclosure, the Motor and the Operator's
Control Station
You must ground both the control and power wiring.
Step 1. Locate the drive ground points as shown in figures 2.8 through 2.13.
Step 2. Run a suitable equipment grounding conductor unbroken from any drive
ground point (see step 1) to the plant ground (grounding electrode). A ring
lug is recommended at the ground point.
Step 3. Connect a suitable grounding conductor from each conduit to this drive
ground point
Step 4. Connect a suitable equipment grounding conductor to the motor frame, the
transformer enclosure if used, and the drive enclosure. Run this conductor
unbroken to the grounding electrode.
Step 5. Connect the GND (green/ground) wire brought in with the incoming AC
power line to the drive ground point.
Step 6. Tighten chassis ground connections per table 2.1.
ATTENTION:The user is responsible for conforming to the National
Electric Code (NEC/CEC) and all other applicable local codes. Wiring
practices, grounding, disconnects, and overcurrent protection are of
particular importance. Size and install wiring in conformance with the
NEC/CEC and all other applicable codes. Failure to observe this
precaution could result in severe bodily injury or loss of life.
ATTENTION:The drive requires a three-phase power source of either
230, 380, 415, or 460 VAC, 50 or 60 Hz. If the correct voltage is not
available, a transformer must be installed between the power source and
the drive. Do not connect the drive to a power source with available
symmetrical short circuit capacity in excess of the power source capacity
listed in Appendix A, tables A.6 and A.7. Failure to observe these
precautions could result in bodily injury or equipment damage
Step 1. Size the AC line supply conductors for the specific drive rating and according
to all applicable codes.
Step 2. Connect the AC line supply to the termination points located at the right top
of the drive or to the disconnect. See figures 2.14 through 2.17.
Step 3. (Integrator drives only) Connect the line fuses (1FU, 2FU, 3FU), field fuses
(6FU, 7FU, 8FU), and the FN contactor to the drive as shown in figure 2.18.
Note that the line and field fuses must be wired as shown in figure 2.18 to
ensure proper phase relationships.
Step 4. (Integrator drives only) Connect the AC line supply to the line fuses (1FU,
2FU, 3FU).
Step 5. Tighten incoming AC line connections per table 2.3.
ENERCON INDUSTRIES 134089-1 BOARD LM5407-02, FD6451-02, SD1957-02
INDRAMAT DSM2.1-S11-01.RS
ALLEN BRADLEY 1756-DNB DEVICENET BRIDGE/SCANNER
NIB HYDE PARK MICROSONIC SM201 PRXOIMITY SENSOR 420851 14-24VDC 20MA
FISHER CONTROLS 41B7289X022-91 RELAY OUTPUT BOARD CL6774X1-A2 REV. H, CL6774
FANUC A20B-1003-0340/02A PC BOARD A20B-1003-0340
VICKERS ASSY. 732 369 EG-09210 DIGITAL I/O BOARD EG09210 732367
REPAIRED HONEYWELL 620-0080 PROCESSOR MODULE 620 25/35
REPAIRED GE 193X643ABG222
DET TRONICS DE1777AT UV SENSOR MODULE 002181-01, 002326-01 REV. A
CONTROL CONCEPTS 3639/3839/3869
GENERAL ELECTRIC 6VFW2200 STATOTROL II DRIVE 6VFWC2200A4 6VRC2000A2
TOL-O-MATIC BC2211892 PNEUMATIC ACTUATOR BC2491066 CONFIG: BC215 SK10 TT2 SH2
BETTIS CBA315 PNEUMATIC ACTUATOR 40/120PSI, -20/200F
SCHNEIDER MODICON 140CPS21400 POWER SUPPLY 8AMP 24VDC, PV: 03, RL: 19
SCHNEIDER AUTOMATION 171CCS76000 PROCESSOR ADAPTER 256K, RS232, I/O BUS
SERVO DYNAMICS SDBDTL925-34 BOARD PART NO. 7300-8103
J.W. HARLEY INC. 40016MP POWER & ALARM PINGER BOARD ASY. 40021MP
GENERAL ELECTRIC 6VAF343005B-A2 VARIABLE FREQUENCY DRIVE AF-300
ALLEN BRADLEY 1784-KTX
FANUC A16B-3200-0054/06B OPTION BOARD A16B-3200-0054 W/ A20B-2902-0198/02A
A20B-2901-0960/05C
PRAXAIR SM-8100 JUNCTION
NEW TEXAS NUCLEAR 885740 I/O
STANLEY X5390 DISPLAY FOR T801 W/ 31106-03 DISPLAY UNIT MODULE 03601-85
HONEYWELL 365754-6 SERVO MOTOR 3657546, 120V 60CPS 11.5W GEAR RATIO 10:1
FANUC A16B-3200-0054/03A OPTION BOARD A16B-3200-0054 W/ A20B-2902-0192/02A
ALLEN BRADLEY 1775-MX A MEMORY COMMUNICATION MODULE 1775MX P/N: 96059675
Siemens Moore 16147-51-2 ACM Transition Board Control Module was added in Jan 2018
Siemens Moore 16147-51-2 ACM Transition Board Control Module has been viewed 385 times
20 More Products from XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD. :