GE Multilin MM200-XXH2S
Company Information:
Name: |
GE Multilin MM200-XXH2S |
Category: |
|
Offered by: |
|
GE Multilin MM200-XXH2S Description:
General Electric GIVEN YOUR BEST ! PLEASES mailto:unity@mvme.cn
Contact: Sandy Lin
Email:unity@mvme.cn
Skype:onlywnn_1
Telegram:+8618020776786
Mobile(Whatsapp): (+86)-18020776786
QQ :2851195456
General Electric Company is an Americanmultinational conglomerate incorporated in New Yorkand headquartered in Boston, Massachusetts. As of2018, the company operates through the followingsegments: aviation, healthcare, power, renewableenergy, digital, additive manufacturing, venture capitaland finance, lighting, transportation, and oil and gas.
GE’s Jenbacher Gas Engines
GE’s gas engines are available in the 0.3-9.5MW electrical output range for an individual unit. Jenbacher gas engines are renowned for robust performance in challenging conditions and difficult fuel gases. GE’s Jenbacher gas engines are manufactured in the town of Jenbach, Austria in the Tyrol. The Jenbacher gas engine is designed to run solely on different types of gas, and for different types of applications. Jenbacher has led the way in gas engine innovation over the last 50 years with developments including:
The LEANOX control philosophy
The world’s first 20 cylinder gas engine
The world’s first 24-cylinder gas engine
The world’s first twin-turbocharger gas engine
The high-efficiency 4-series concept
Gas Engine Basics
The image below shows the basics of a stationary gas engine and generator used for the production of power. It consists of four main components – the engine which is fueled by different gases. Once the gas is burnt in the cylinders of the engine, the force turns a crank shaft within the engine. The crank shaft turns an alternator which results in the generation of electricity. Heat from the combustion process is released from the cylinders This must be either recovered and used in a combined heat and power configuration or dissipated via dump radiators located close to the engine. Finally and importantly there are advanced control systems to facilitate robust performance of the generator.
Power Production
GE Jenbacher gas engines can be configured to produce:
Electricity only (base-load generation)
Electricity & heat (cogeneration / combined heat & power – CHP)
Electricity, heat and cooling water (trigeneration / combined heat, power & cooling – CCHP)
Electricity, heat, cooling and high-grade carbon dioxide (quadgeneration)
Electricity, heat and high grade carbon dioxide (greenhouse cogeneration)
Gas engines are typically applied as stationary continuous generation units but can also operate as peaking plants & in greenhouses to meet fluctuations in local electricity demand. They can produce electricity in parallel with the local electricity grid, in island mode operation, or for power generation in remote areas.
Guarantee & Returns
1. All products we sell are 100% New original Package.in good condition and will be examed before they are shipped. We will try our best to avoid any quality problems.
2. We offer 12 month warranty after receiving parcels. If there are some workmanship or material defects with the products, please contact us firstly, we will exchange it or offer other solutions for you to make a choice.
3. The shipping and handling charge is not refundable and customer should be responsible for all the charges of unreasonable returning and reshipping. All return items must be in good condition. They must under resalable condition. Man-made defects are not guaranteed, such as broken, scratched and so on. Thanks for understanding and cooperation!
Packing & Delivery
1)100% full New! - Original Factory Seal !
2)Warranty: 12 months!
3)Package: Original packing with cartons.
4)Delivery time: Shipped in 3 days after payment
5)ship to you via DHL/TNT/UPS/EMS/Fedex.
6) All the goods will be tested before shipment.
Type of payment:
T/T 100% Payment in Advance
Refound or Replacement:
We accept return back itmes if the goods still remain in their original condition on the warranty time
mailto:unity@mvme.cn
Our Partner
We have large of inventory for our company's
advantage products
some of kinds of DCS/PLC parts as below
1) IS200/DS200 series Excitation system card
2)IC693/IC695/IC697/IC698/IC200/IC660/IC670 CPU module,Communication module, Analog Digital module
GE Multilin MM200-XXH2S
GE Multilin MM200-XXH2S
GE Multilin MM200-XXH2S
Five of the six output relays are always non-failsafe; the 6 SERVICE relay is always failsafe. As failsafe, the 6 SERVICE relay will be energized normally and de-energize when called upon to operate. It will also de-energize when control power to the 469 is lost and therefore, be in its operated state. All other relays, being non-failsafe, will be de-energized normally and energize when called upon to operate. Obviously, when control power is lost to the 469, the output relays must be de-energized and therefore, they will be in their nonoperated state. Shorting bars in the drawout case ensure that when the 469 is drawn out, no trip or alarm occurs. The the 6 SERVICE relay will however indicate that the 469 has been drawn out.
BBC Brown Boveri GH R 462 0000 VO
Siemens 5SY6 625-7 5SY6625-7 -OVP-
Lenze EVF8202-G-V011 EVF8202G-V011 Frequenzumricht?er
Siemens SIMATIC S5 6ES5464-8ME11 6ES5 464-8ME11 E-Stand: 8
GESTRA Rückschlagventi?l RK 44 DN 150 (6")
Allen-Bradley 1756-OB16E/A Control Logix
SEW Eurodrive R40 DT80N4TF
Siemens Simatic S5 6ES5456-7LA11 6ES5 456-7LA11 E-Stand: 02 -OVP-
Euchner NZ2VZ-528E NZ2VZ528E Nr.034398
B&R 5P62:JORNED-01 5P62:JORNED-02
Hydac ?lfilterpumpe FLS-1/1.0/P+V/5?/ OLF-5 Serie
Siemens Sicherungslastt?renner 3NP4070-0CH01 3NP4 070-0CH01
ABB ACS550-01-015A-?4 ACS55001015A4
SIEMENS Sinamics Sensor Module SMC20 6SL3055-0AA00-5?BA1 6SL3 055-0AA0-5BA1 E: B
CompAir No. CF 0240 E-TS Feinstfilter Kit CE 0258 B-TS
Sauer-Danfoss Hydraulic Motor OMV 315 151B3100
Endress Hauser TC15 TC15-H1B2Y1K0HA?12Y Range: 0...800C
Siemens C53207A 351D653 1 bzw. C53207A351D6531
ABB Servomotor 8C403000MA02SG3?MB
SIEMENS ISKAMATIC B HA11 6FQ2951-0AE -OVP-
SEW Eurodrive MDS60A0022-5A3-?4-00 MDS60A00225A340?0
Siemens 6SE6400-0BP00-0?AA0 6SE6 400-0BP00-0AA0 E-Stand B09/1.03
Siemens Simatic S5 6ES5921-3UA12 6ES5 921-3UA12
St?ber FDS 1030/B
E.Dold&S?hne BA9053/012 BA 9053 012 AC 0,1-1 A
SEW Eurodrive S57 DT80K4/TF
AEG T-SV1 TSV1
Siemens 3VL9800-2AE00 -OVP-
Leuze electronic Konturflex KT 20-1760 Lichtvorhang
Siemens SIMATIC S5 6ES5452-8MR11 6ES5 452-8MR11 E-Stand: 02
Siemens C53207A 351D653 1 bzw. C53207A351D6531
Siemens Motorantrieb mit Speicher 3VL9400-3MQ00 LR 3VL94003MQ00LR
GE Multilin MM200-XXH2S was added in Oct 2018
GE Multilin MM200-XXH2S has been viewed 103 times
20 More Products from XIAMEN YUEHANG COMPUTER ENGINEERING CO.LTD. :