Industry Directory | Manufacturer
A leader in automated fluid dispensing, jetting, and conformal coating. Products include stand-alone dispensing workstations and fully automated, in-line conveyorized systems with advanced process controls.
Industry Directory | Manufacturer
Global supplier of advanced thermal processing equipment and processes to the electronics assembly market.
New Equipment | Board Handling - Conveyors
Model No: KSUN 250 Automatic Sucking Loader PCB loading time: Approx 6seconds Magazine change-over time: Approx 30 seconds Power supply: 100-230V AC (customized ), single phase, MAX 300V/A Air pressure: 4-6 bar, MAX 30L/minute Transport height:
New Equipment | Board Handling - Conveyors
Model No: KSUN 460 Automatic Sucking Loader PCB loading time: Approx 6seconds Magazine change-over time: Approx 30 seconds Power supply: 100-230V AC (customized ), single phase, MAX 300V/A Air pressure: 4-6 bar, MAX 30L/minute Transport height:
Electronics Forum | Tue Aug 15 07:27:03 EDT 2017 | emeto
Most important factor - temperature. Back in the days I worked for a place without AC, and summer time this paste couldn't make it for more than an hour. In controlled environment you will be safe for hours or even a shift.
Electronics Forum | Mon Aug 14 15:09:14 EDT 2017 | charliedci
In my experience, in a temperature/humidity controlled environment, 1 hour, no big deal. 4 hours still ok. Overnight your pushing the limits but will probably reflow without issues. Any longer, could be a problem. Again, a lot depend on type of past
Used SMT Equipment | Chipshooters / Chip Mounters
Refurbished YV180XG Pick and Place Machine Panel size L Type: Max L380 x W330 mm ∼ Min L50 x W50 mm Panel thick 0.4 ~ 3.0 mm Mounting ±0.05 mm (0.01mm control) Mounting angle ±180° (0.01° control) Mounting speed 0.095 se
Used SMT Equipment | Soldering - Reflow
Vintage: 2006 Details: • 7 zone, 1 cooling zone • Rail & Mesh • No center rail support • Auto chain oiler (not enabled) • Controller: Intellimax 2 • Software rev: Wiscon 6.0 • Has air cooling
Industry News | 2011-11-20 13:36:13.0
GPD Global has been awarded two Global Technology Awards in the categories of Adhesives/Coatings/Encapsulants and Dispensing Equipment for its PCD Dispensing on the MAX Series Platform
Industry News | 2012-03-05 14:26:45.0
GPD Global has been awarded a 2012 NPI Award in the category of Dispensing Equipment for its PCD Dispensing on the MAX Series Platform.
Parts & Supplies | Screen Printers
1015792 ;MPM CCM,RCM control panel
Parts & Supplies | Pick and Place/Feeders
control panel vacuum pump
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
http://www.pcb-separator.com/html/PRODUCTS/PCB%20separator/2015/0607/132.html PCB cutting machine/guillotine separator/PCB depaneling machine/PCB panel separator ASCEN specializing the SMT assmebly line equipment manufacture the more detail please ch
http://www.pcb-separator.com/html/PRODUCTS/PCB%20separator/2015/0607/132.html PCB cutting machine/guillotine separator/PCB depaneling machine/PCB panel separator ASCEN specializing the SMT assmebly line equipment manufacture the more detail please ch
Training Courses | | | PCB Design Courses
The PCB design courses teach students the process, techniques and tools needed to design layout of printed circuit boards.
Training Courses | | | Other Courses
Other courses related to electronics manufacturing and assembly
Events Calendar | Thu Jan 10 00:00:00 EST 2019 - Thu Jan 10 00:00:00 EST 2019 | Manassas, Virginia USA
SMTA Capital Chapter: Operation of a Vacuum Reflow Oven with Preliminary Void Reduction Data
Events Calendar | Tue Nov 05 00:00:00 EST 2019 - Tue Nov 05 00:00:00 EST 2019 | North Billerica, Massachusetts USA
Free Vacuum Reflow Workshop
Career Center | Twinsburg, Ohio USA | Maintenance
We are in need of Universal/Fuji machine operators, Alternative machines to the Universal are listed below. SMT machines (Fuji, Panasonic, Quad, Siemens, Dek, BTU, Electrovert, Heller, Phillips) Location: Twinsburg (Ohio), saburb of Cleveland It is a
Career Center | North Billerica, Massachusetts USA | Technical Support
Description of Duties: Interfaces directly with customers, representatives, field engineers on the phone and in person regarding questions of operations, maintenance and or applications of the equipment. Collaborates with engineers to review
Career Center | Fort Worth, Texas USA | Engineering,Maintenance,Production,Quality Control,Research and Development
A mechanically-inclined, results-oriented, lean-driven professional with proven success in implementing programs that result in efficiencies and cost savings. Effectively communicates with diverse audiences, encourages training and employee developme
Career Center | 厦门, China | Sales/Marketing
It supplies automation components to heavy industry manufacturers around the world. We have plc, DCS, operation panel, servo drive and servo motor, excitation plate, other electrical equipment accessories inventory, also provide production products.
Heller Industries Inc. | https://hellerindustries.com/parts/438260/
438260 - Control Panel of Chiller Phone 1-973-377-6800 Company About News Events New Equipment Convection Reflow Ovens Reflow Oven MK7 -New
| https://www.feedersupplier.com/sale-13119559-smt-feeder-spare-part-00348942s01-siemens-asm-cable-control-panel-distribuitor-panel-siemens-s-serie.html
SMT feeder spare part 00348942S01 Siemens/ASM Cable control panel Distribuitor panel siemens S series feeders Leave a Message We will call you back soon