Industry Directory: pull test fail (12)

CAMI Research Inc.

Industry Directory | Consultant / Service Provider / Manufacturer

CableEye® continuity and HiPot pass/fail & diagnostic Cable & Harness Test Systems w simple scripting, labeling, documentation, cataloging & relay control. Dynamically display continuity, Ω, diodes, IR, dielectric breakdown & more

Pinnacle Data Systems, Inc

Industry Directory | Manufacturer

PDSi provides products and technical services, encompassing the development and production of embedded (built-in) or stand alone computer systems and components, and the testing and repair of computer systems, components and peripherals, to OEMs.

New SMT Equipment: pull test fail (99)

ezLOAD PCB Support System

ezLOAD PCB Support System

New Equipment | Board Handling - Pallets,Carriers,Fixtures

Count On Tools Inc., a leading provider of precision components and SMT spare parts, introduces the new ezLOAD PCB Support System. With the recent increase of densely populated double-sided circuit boards, COT recognized the need for more affordable

Count On Tools, Inc.

PullTester 26 - Pull Testing Machine

PullTester 26 - Pull Testing Machine

New Equipment | Cable & Wire Harness Equipment

Overview Schleuniger's PullTester 26 is a dual-range, motorized benchtop device designed to measure pull forces of wire crimp connections as well as ultrasonic metal welding connections on a wider range of wire than single-range pull test devices.

Schleuniger, Inc.

Electronics Forum: pull test fail (592)

lead pull out issue

Electronics Forum | Wed Aug 25 21:25:28 EDT 2004 | davef

First as a nit, your �substrate� is probably NOT copper. It�s probably FR4 fiberglass/epoxy. Substrate. Base Material. A supporting insulating material upon which parts, components, and elements are attached. Second, enough of that, on to your i

AOI false fail PPM

Electronics Forum | Fri Aug 08 13:21:14 EDT 2008 | RobP

With AOI it really depends on what you are testing. Not only what criteria, but what different types of components. We run a high volume low mix application for automotive checking for presense, positional accuracy, and all solder joints. We curre

Used SMT Equipment: pull test fail (75)

Dage Dage4000 pull tester machines

Dage Dage4000 pull tester machines

Used SMT Equipment | Semiconductor & Solar

Dage 4000  pull test machines for Brond machines take with 2 module :250g+5000g form USA factory user, good work condition atten: steven wong  email: 13560819457@139.com

HongCheng import & Export co.,Ltd

Dage Series 4000 Bondtester

Dage Series 4000 Bondtester

Used SMT Equipment | Semiconductor & Solar

Bondtester by DAGE, in good condition. DAGE Series 4000 Bondtester product information. The 4000 bondtester is multipurpose, capable of performing all pull and shear applications. The 4000 bondtester can be configured as a simple bond wire pull

Fix Trade BV

Industry News: pull test fail (229)

GPD Global Live Demos at IPC APEX in Las Vegas Convention Center

Industry News | 2016-02-27 22:07:08.0

GPD Global will exhibit in Booth#1818 at the upcoming IPC APEX EXPO 2016 Conference and Exhibition. See a live demonstration of 01005 dispensing on the MAX series high precision dispenser, the intuitively programmed Island series benchtop dispenser, and a full range of dispense pumps used on GPD dispense systems.

GPD Global

Introbotics Announces New Board Testing Capability for Merix Corporation

Industry News | 2003-04-01 08:13:08.0

The Introbotics equipment boosts controlled impedance testing productivity and accuracy by a factor of ten compared to the handheld probing techniques.

SMTnet

Parts & Supplies: pull test fail (13)

Siemens TEST PCB LP3

Siemens TEST PCB LP3

Parts & Supplies | Assembly Accessories

TEST PCB LP3  ..00359534-01 Tester PEL-2002A  ​ Push pull tester NK-500  ​ Neon lamp tester SX-C  Test Probes (Universal Probe) TL20 Probes  Connector Test Point temp (Male) SMPW-K-M.  ​ DIP TESTER DS-10

Qinyi Electronics Co.,Ltd

Siemens TEST PCB LP3

Siemens TEST PCB LP3

Parts & Supplies | Assembly Accessories

TEST PCB LP3  ..00359534-01 Tester PEL-2002A  ​ Push pull tester NK-500  ​ Neon lamp tester SX-C  Test Probes (Universal Probe) TL20 Probes  Connector Test Point temp (Male) SMPW-K-M.  ​ DIP TESTER DS-10

Qinyi Electronics Co.,Ltd

Technical Library: pull test fail (20)

Why salt spray chamber fail to spray salt mist?

Technical Library | 2019-11-20 22:44:25.0

Salt spray test chamber is used to test teh salt corrosion resistance ability of hardware, metal and other auto parts,the chamber can quickly detect the corrosion resistance degree of products in the temperature, humidity and salt spraying environment, which can effectively improve production efficiency. So what is the reason why such a salt spray test chamber does not spray? As per our past maintenance experience,there are below reasons,customers can have a look,hope it is helpful: 1, the spray tower is blocked; 2, water pipes clogged, water flow can not go in; 3, the air compressor stops running,pls open the air compressor button; 4, main switch of the air compressor outlet is not turned on,pls turn on. 5, the solenoid valve fails, the pressure meter is broken or the pressure is too low, pls check with Climatest and repair it. 6, when the nozzle is clogged, the nozzle should be carefully removed and cleaned,because it is fragile. 7, if the spray pressure is normal, the position of the nozzle glass is also correct, but what is the reason for not spraying? In this case, it is necessary to carefully observe whether there is dirt at the contact surface of the nozzle. If so, clean up the dirt and the spray can be carried out normally. That‘s all we‘re going to talk about today. If you have any questions, follow us on facebook, Please feel free to ask us questions.

Symor Instrument Equipment Co.,Ltd

When you pull out the nitrogen pipe of nitrogen cabinet

Technical Library | 2019-11-07 03:07:12.0

Many customers who have purchased the nitrogen cabinets have been in the mistaken belief that the air pipe can be pull down hard,so that it can cause the board to be damaged due to the hard pulling of the air pipe, which leads to the replacement of the penetrating board. Now, the following pictures are provided. Please note: Nitrogen cabinet is a optiomal choice for the microelectronics,semiconductor for humidity proof and anti-oxidation purpose,Climatest has put much efforts on the R&D of dry cabinets,as you know,our advangtage is to handle temperature and humidity,since early 1990s,our engineers began to test and research dry cabinet and nitrogen cabinet,all of our manufacturing process strictly follow ISO9001 standard,we supply to international customers for 20 years,if you are still looking for a reliable dry cabinet manufacturer to protect your MSD from moisture related damage,come to visit www.climatechambers.com,we are ready!

Symor Instrument Equipment Co.,Ltd

Videos: pull test fail (12)

Electrovert Cleaning

Electrovert Cleaning

Videos

The Electrovert Aquastorm is a versatile, high performance cleaning system designed to optimize the PCB cleaning process while minimizing overall cost.  The Aquastorm features the most advanced cleaning technologies in an energy-efficient design

ITW EAE

Electrovert Cleaning

Electrovert Cleaning

Videos

The Aquastorm 200 Stainless Steel cleaning system with dual wash, dual chemical isolation and Torrid Zone dryer provides complete cleaning performance with fast throughput capability and optimal process flexibility. The Electrovert Aquastorm is a ve

ITW EAE

Training Courses: pull test fail (2)

Failure Analysis and Reliability Testing in Electronics Manufacturing

Training Courses | | | PCB Inspection Courses

The PCB inspection courses focus on improving PCB yield and reliability through validation and detection of defects on electronics assemblies.

ACI Technologies, Inc.

IPC/WHMA-A-620 Trainer (CIT) Certification Training Course

Training Courses | | | IPC/WHMA-A-620 Trainer (CIT)

The Certified IPC/WHMA-A-620 Trainer (CIT) courses recognize individuals as qualified trainers in the area of cable and wire harness fabrication and installation, and prepares them to deliver Certified IPC/WHMA-A-620 Specialist (CIS) training.

Circuit Technology Inc.

Events Calendar: pull test fail (4)

Corrosion Testing For Electronic Equipment

Events Calendar | Tue Feb 18 00:00:00 EST 2020 - Tue Feb 18 00:00:00 EST 2020 | ,

Corrosion Testing For Electronic Equipment

CALCE Center for Advanced Life Cycle Engineering

FREE Webinar: Eliminate Circuit Board Problems and Failure Modes

Events Calendar | Tue Jan 23 00:00:00 EST 2018 - Tue Jan 23 00:00:00 EST 2018 | New Milford, Connecticut USA

FREE Webinar: Eliminate Circuit Board Problems and Failure Modes

Vision Engineering Inc.

Career Center - Jobs: pull test fail (17)

Electronic Technician

Career Center | Portland, Maine USA | Engineering

SKILLS: Oscopes & Multimeters; Tshoot PCB's to component level; Good understanding of Basic Electronics; 2yr degree helpful. JOB DESCRIPTION: * Test fiber optic based PCB's utilizing software scripts * Perform environmental testing, track cycle time

Adecco Technical

Material Lab Technician

Career Center | Milpitas, California USA | Engineering,Production,Quality Control,Research and Development,Technical Support

Winslow Automation, Inc. (aka Six Sigma), an industry leader in electronic component interconnect technology & related test and failure analysis services, is seeking individuals specializing in materials lab testing to join our team. We have openin

Winslow Automation (aka Six Sigma)

Career Center - Resumes: pull test fail (6)

Detail Oriented

Career Center | north augusta, South Carolina USA | Production,Quality Control

Detail oriented!

Self motivated SMT operator

Career Center | north augusta, South Carolina USA | Production,Quality Control

I am a skilled smt operator that pays close attention to detail! With my experience in the electronic field for the passed 10 years proving to be an asset to all companies that i have worked for in providing quality work and ensuring on time delivery

Express Newsletter: pull test fail (834)

SMTnet Express - May 9, 2019

SMTnet Express, May 9, 2019, Subscribers: 31,902, Companies: 10,760, Users: 26,083 Cold Ball Pull Test Efficiency for the PCB Pad Cratering Validation with the Ultra Low Loss Dielectric Material Credits: iNEMI (International Electronics

Partner Websites: pull test fail (1510)

Footprint Error Pad-Pad clearance fail - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/footprint-error-padpad-clearance-fail_topic2283.html

Footprint Error Pad-Pad clearance fail - PCB Libraries Forum   Forum Home > PCB Footprint Expert > Questions & Answers    New Posts    FAQ    Search    Events    Register    Login Footprint Error Pad-Pad clearance fail

PCB Libraries, Inc.

Gold Wire Bond Failing Pull Test - EPTAC - Train. Work Smarter. Succeed

| https://www.eptac.com/ask/gold-wire-bond-failing-pull-test/

Gold Wire Bond Failing Pull Test - EPTAC - Train. Work Smarter. Succeed Looking for solder training standards, manuals, kits, and more


pull test fail searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next
Circuit Board, PCB Assembly & electronics manufacturing service provider

Wave Soldering 101 Training Course
Conductive Adhesive & Non-Conductive Adhesive Dispensing

Software for SMT placement & AOI - Free Download.
Voidless Reflow Soldering

Training online, at your facility, or at one of our worldwide training centers"
SMT feeders

Smt Feeder repair service centers in Europe, North, South America
SMTAI 2024 - SMTA International

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
Electronic Solutions R3

Training online, at your facility, or at one of our worldwide training centers"