Industry Directory | Manufacturer
ASLi main products: Temperature (humidity) chamber, Thermal Shock Test Chamber, Sand and Dust Tester , Rain Spray Tester, UV Chamber, Ozone Chamber, Xenon Climate Chamber , Salt Spray Corrosion Chamber, High Temperature (Vacuum )
Industry Directory | Consultant / Service Provider
Design and manufacture of thermal systems for rapid temperature verification and testing, and process cooling. Includes small-footprint thermal chambers and plates, mobile temperature forcing systems, and process chillers.
Dual Chamber Module - Dual Chambers + Dual Blowers + Dual Heaters + Dual T/Cs. Bifurcated (Dual) chamber reflow oven allows 2 different thermal profiles to run simultaneously in the same reflow oven foot print Improved temperature uniformity acro
Dual Lane SMT Reflow Oven Nitrogen soldering process dual rail conveyor Weight Appx.:3060Kg Dimension 6300*1680*1530mm Product description: 10 Zones Dual Rail Nitrogen SMT Reflow Oven KTR-1000D-N Manufacturer, Nitrogen soldering process, dual
Electronics Forum | Thu Dec 07 15:51:02 EST 2000 | gsubbert
We have an old Blue M temperature chamber. We have no manuals for it and no information on how to make the cams to get the temperature profile that we need. If anyone has any information and would be willing to share it with me I would appreciate it.
Electronics Forum | Fri Dec 08 19:10:29 EST 2000 | Dave F
Try these guys, they do more environmental ovens than your momma!!! LR Environmental 12902 S.Spring St Los Angeles CA 90061 800.574.2748 213.770.0634 fax0105 sales@lre.com www.lre.com John Kline
Used SMT Equipment | In-Circuit Testers
1988 Thermotron FA-4-CH-1-1 Environmental Chamber Temperature Range: -73C to 177C (-99F to 351F) Control Accuracy: 1.0+/- C Internal Dimensions: 20" x 20" x 20" External Dimensions: 32" x 34" x 82" Power: 208VAC; 28A; 60Hz; 3 Phase Serial: 165
Used SMT Equipment | General Purpose Equipment
Tenney - Blue M Thermal Shock Chamber For Sale See attached pictures and information below Equipment Information Tenney - Blue M - TPS Model Number: WSP-109 Serial Number: 0801000082 Year: 2007 Type: Hot Cold - Shock
Industry News | 2003-06-25 12:28:40.0
The chart includes a variety of diagrams, tables, and ratio charts for RF Emissions; Direct RF Power Injection; Bulk Current Injection (BCI); ESD and Transients; as well as TEM Cell and Stripline testing.
Industry News | 2016-10-10 10:59:34.0
Sypris Electronics will be liquidating some of their assets utilizing the online auction services of Baja Bid. The bidding for this event will open promptly at 7:00am EDT on october 24, 2015 and the closing will begin at 11:00am EDT on November 11, 2016.
Parts & Supplies | SMT Equipment
Original Smt spare parts JUKI 40053181 775 TEMPERATURE BLIND CONTROLLER HD00176000 JUKI Nozzle Specifications: Brand Name JUKI TEMPERATURE BLIND CONTROLLER Part Number 40053181 Model Number HD00176000 Ensure Tested buy juki Guarantee 1 mont
Parts & Supplies | Soldering - Reflow
This reflow oven is top quality oven represent the world's best low cost, high performance solder reflow sytem. The sensor is designed in the front of tip and the temperature induction is very exact and sensitive, the speed of heating and recovery of
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Technical Library | 2019-11-17 22:46:45.0
Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers
ACI Technologies Inc. (ACI) is a scientific research corporation dedicated to the advancement of electronics manufacturing processes and materials for The Department of Defense and industry. This video provides an overview of our commercial service
Events Calendar | Wed Apr 19 00:00:00 EDT 2017 - Fri Apr 21 00:00:00 EDT 2017 | Nara, Japan
Ceramic Interconnect and Ceramic Microsystems Technologies (CICMT 2017)
International Microelectronics Assembly and Packaging Society (IMAPS)
Career Center | Bangalore, India | Engineering,Management,Production,Quality Control,Technical Support
WORK EXPERIENCE DETAILS: 7+ Years of Experience in manufacturing & hardware testing of Protocol conveter & Commissioning, Products delivery and QA/QC. 2+ Years of Experience in Hardware testing and Package Level testing. 2+ Years of Experience in
Article Return to Front Page A Low Temperature Alte
Article Return to Front Page A Low Temperature Alte
1st Place Machinery Inc. | http://www.firstplacemachinery.com/firstplace_cincinnati_subzero_environmental_chamber_oven.html
cincinnati sub zero chamber oven Cincinnati Sub Zero Model Number: Z-8-1-1-H/AC Serial Number: ZE9021294 Type: Low Temperature Environmental Test Chamber Digital programmable controller Temperature limit controller Communication port Temp. Range: -73 to
ASYMTEK Products | Nordson Electronics Solutions | https://www.nordson.com/en/divisions/industrial-coating-systems/additional-product-sub-type/temperature-conditioning?con=t&page=7
: Temperature Conditioning Model A7A Color-Change Valves Industrial Coating Systems Single or dual-chamber automatic spray guns for versatile, reliable high-production airless