New SMT Equipment: test and point and flux (20)

IPC-A-600 Instructor (CIT)  - Training and Certification

IPC-A-600 Instructor (CIT) - Training and Certification

New Equipment | Education/Training

Bare Board Inspection Training This 3-day, lectured course utilizes the images in the IPC-A-600 document to provide visual accept/reject criteria examples for all three classes of bare board fabrication and inspection. The IPC-A-600, “The Acce

EPTAC Corporation

Test unit for in-circuit, functional and end test

Test unit for in-circuit, functional and end test

New Equipment | Test Equipment

The ENGMATEC test handler is characterized by the wide-ranging spectrum of applications for in-circuit, functional or end tests. All components of the module system are matched with each other and can be combined with each other as well as with vario

ENGMATEC GmbH

Electronics Forum: test and point and flux (89)

Wave flux and profiling

Electronics Forum | Wed Dec 20 04:43:36 EST 2006 | greg york

Any decent flux would volatise off with the heat of the wave unless absorbed into the solder mask. Test this by trying to clean in alcohol or common solvent aerosol, if it does not clean then it is probably Mineral Salts from solder mask fillers. Ano

SMT Solder paste and wave flux evaluation

Electronics Forum | Fri Jan 28 12:29:01 EST 2005 | Bob R.

We use the exact same method Chunks outlined for evaluating just about anything we're going to roll out worldwide, whether it's a material or a machine. List your factors (print speed, solder spread, etc), assign each a weight, evaluate each paste a

Used SMT Equipment: test and point and flux (1)

Universal Instruments GSMxs 5785A Advanced Semiconductor & SMT  Pick and Place W/ Flux

Universal Instruments GSMxs 5785A Advanced Semiconductor & SMT Pick and Place W/ Flux

Used SMT Equipment | Pick and Place/Feeders

Universal Instruments GSMxs Advanced Semiconductor and SMT Pick and Place Machine Model 5785A    Very Low Cycle Counter only 723,974 Cycles. UPS+ 6.1.0.5 Software Unovis ASA, Windows OS Linear Motor Technology  Four Spindle C4

4 Tech Electronics Inc.

Industry News: test and point and flux (226)

Repair Services Being Outsourced by OEMs and EMS Firms

Industry News | 2003-03-06 08:43:16.0

Under pressure to fulfill growing repair obligations in the United States, some OEMs and EMS companies are outsourcing projects to product-lifecycle managers.

SMTnet

Low-Cost UNIX- and PC-Based Boundary-Scan Upgrade for Agilent 3070 In-Circuit Testers

Industry News | 2003-04-03 08:51:07.0

Symphony 3070TM Package from JTAG Technologies for Testing and In-System Flash / PLD Programming

SMTnet

Parts & Supplies: test and point and flux (1)

KIC KIC X5 Thermal Profiler with SPC software and RF capability For Reflow

KIC KIC X5 Thermal Profiler with SPC software and RF capability For Reflow

Parts & Supplies | Assembly Accessories

Detailed Product Description Features: 7 Channel Brand: KIC Part Name: X5 Reflow Profiler Model: X5 Condition: Original New Leadtime: 7days KIC X5 Thermal Profiler with SPC software and RF capability For Reflow Track More Data Points With 7,

KingFei SMT Tech

Technical Library: test and point and flux (17)

Maintenance and operation of walk-in temperature humidity test chamber

Technical Library | 2019-11-17 22:46:45.0

Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers

Symor Instrument Equipment Co.,Ltd

Comparison of ROSE, C3/IC, and SIR as an effective cleanliness verification test for post soldered PCBA

Technical Library | 2023-04-17 21:17:59.0

The purpose of this paper is to evaluate and compare the effectiveness and sensitivity of different cleanliness verification tests for post soldered printed circuit board assemblies (PCBAs) to provide an understanding of current industry practice for ionic contamination detection limits. Design/methodology/approach – PCBAs were subjected to different flux residue cleaning dwell times and cleanliness levels were verified with resistivity of solvent extract, critical cleanliness control (C3) test, and ion chromatography analyses to provide results capable of differentiating different sensitivity levels for each test. Findings – This study provides an understanding of current industry practice for ionic contamination detection using verification tests with different detection sensitivity levels. Some of the available cleanliness monitoring systems, particularly at critical areas of circuitry that are prone to product failure and residue entrapment, may have been overlooked. Research limitations/implications – Only Sn/Pb, clean type flux residue was evaluated. Thus, the current study was not an all encompassing project that is representative of other chemistry-based flux residues. Practical implications – The paper provides a reference that can be used to determine the most suitable and effective verification test for the detection of ionic contamination on PCBAs. Originality/value – Flux residue-related problems have long existed in the industry. The findings presented in this paper give a basic understanding to PCBA manufacturers when they are trying to choose the most suitable and effective verification test for the detection of ionic contamination on their products. Hence, the negative impact of flux residue on the respective product's long-term reliability and performance can be minimized and monitored effectively.

Jabil Circuit, Inc.

Videos: test and point and flux (6)

auto pcb screen printer, auto smt stencil printer , auto solder paste printer , stencil printing machine, PCB solder paste printer

auto pcb screen printer, auto smt stencil printer , auto solder paste printer , stencil printing machine, PCB solder paste printer

Videos

https://www.ascen.ltd/Products/Solder_paste_printer/513.html full auto PCB screen printer and SMT solder paste printing machine with Image and optical system,It is a very accurate fully automatic SMT stencil printer.automatic PCB screen printer main

ASCEN Technology

auto pcb screen printer , auto PCB stencil printer , PCB solder paste printer ,  PCB screen printer, SMT stencil printer

auto pcb screen printer , auto PCB stencil printer , PCB solder paste printer , PCB screen printer, SMT stencil printer

Videos

https://www.ascen.ltd/Products/Solder_paste_printer/513.html full auto PCB screen printer and SMT solder paste printing machine with Image and optical system,It is a very accurate fully automatic SMT stencil printer.automatic PCB screen printer main

ASCEN Technology

Training Courses: test and point and flux (4)

System Level ESD/EMI: Testing to IEC and Other Standards

Training Courses | | | ESD Control Training Courses

Browse training and certification programs for electrostatic discharge (ESD) control in electronics assembly.

EOS/ESD Association, Inc.

Design for Testability and for Built-in Self Test

Training Courses | | | PCB Design Courses

The PCB design courses teach students the process, techniques and tools needed to design layout of printed circuit boards.

A.T.E. Solutions, Inc.

Events Calendar: test and point and flux (5)

Oregon Chapter Tutorial: How Clean is Clean and How Do You Know for Sure?

Events Calendar | Wed Apr 21 00:00:00 EDT 2021 - Wed Apr 21 00:00:00 EDT 2021 | ,

Oregon Chapter Tutorial: How Clean is Clean and How Do You Know for Sure?

Surface Mount Technology Association (SMTA)

Stencil Printing Process and Solder Paste Inspection – An In-Depth Look - SMTA Webtorial

Events Calendar | Wed Apr 18 00:00:00 EDT 2018 - Thu Apr 19 00:00:00 EDT 2018 | ,

Stencil Printing Process and Solder Paste Inspection – An In-Depth Look - SMTA Webtorial

Surface Mount Technology Association (SMTA)

Express Newsletter: test and point and flux (928)

Partner Websites: test and point and flux (2915)

Add Test Point Obstruct in Xpedition Footprint - PCB Libraries Forum

PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/add-test-point-obstruct-in-xpedition-footprint_topic2247.html

Add Test Point Obstruct in Xpedition Footprint - PCB Libraries Forum   Forum Home > PCB Footprint Expert > Questions & Answers    New Posts    FAQ    Search    Events    Register    Login Add Test Point Obstruct in Xpedition Footprint

PCB Libraries, Inc.


test and point and flux searches for Companies, Equipment, Machines, Suppliers & Information

Sm t t t t t t t t t t net
  1 2 3 4 5 6 7 8 9 10 Next