Technical Library: electrical verification fail (Page 1 of 1)

IPC 9252A Electrical Test Considerations & Military Specifications versus Electrical Test

Technical Library | 2013-04-04 15:28:39.0

This paper will outline and define what requirements must be adhered to for the OEM community to truly achieve the IPC class product from the Electrical Test standpoint. This will include the test point optimization matrix, Isolation (shorts) parameters and Continuity (opens) parameters. This paper will also address the IPC Class III/A additional requirements for Aerospace and Military Avionics. The disconnect exists between OEMs understanding the requirements of their specific IPC class design versus the signature that will be presented from their design. This results in many Class III builds failing at Electrical Test... First published in the 2012 IPC APEX EXPO technical conference proceedings

Gardien Services USA

Head-in-Pillow BGA Defects

Technical Library | 2009-11-05 11:17:32.0

Head-in-pillow (HiP), also known as ball-and-socket, is a solder joint defect where the solder paste deposit wets the pad, but does not fully wet the ball. This results in a solder joint with enough of a connection to have electrical integrity, but lacking sufficient mechanical strength. Due to the lack of solder joint strength, these components may fail with very little mechanical or thermal stress. This potentially costly defect is not usually detected in functional testing, and only shows up as a failure in the field after the assembly has been exposed to some physical or thermal stress.

AIM Solder

How Clean is Clean Enough – At What Level Does Each of The Individual Contaminates Cause Leakage and Corrosion Failures in SIR?

Technical Library | 2016-09-08 16:27:49.0

In this investigation a test matrix was completed utilizing 900 electrodes (small circuit board with parallel copper traces on FR-4 with LPI soldermask at 6, 10 and 50 mil spacing): 12 ionic contaminants were applied in five concentrations to three different spaced electrodes with five replicas each (three different bare copper trace spacing / five replications of each with five levels of ionic concentration). The investigation was to assess the electrical response under controlled heat and humidity conditions of the known applied contamination to electrodes, using the IPC SIR (surface insulation resistance) J-STD 001 limits and determine at what level of contamination and spacing the ionic / organic residue has a failing effect on SIR.

Foresite Inc.

  1  

electrical verification fail searches for Companies, Equipment, Machines, Suppliers & Information