Technical Library: humidity temperature (Page 1 of 3)

On Oreology, the fracture and flow of "milk's favorite cookie® "

Technical Library | 2024-08-29 18:30:46.0

The mechanical experience of consumption (i.e., feel, softness, and texture) of many foods is intrinsic to their enjoyable consumption, one example being the habit of twisting a sandwich cookie to reveal the cream. Scientifically, sandwich cookies present a paradigmatic model of parallel plate rheometry in which a fluid sample, the cream, is held between two parallel plates, the wafers. When the wafers are counterrotated, the cream deforms, flows, and ultimately fractures, leading to separation of the cookie into two pieces. We introduce Oreology (/Oriːˈɒl@dʒi/), from the Nabisco Oreo for "cookie" and the Greek rheo logia for "flow study," as the study of the flow and fracture of sandwich cookies. Using a laboratory rheometer, we measure failure mechanics of the eponymous Oreo's "creme" and probe the influence of rotation rate, amount of creme, and flavor on the stress–strain curve and postmortem creme distribution. The results typically show adhesive failure, in which nearly all (95%) creme remains on one wafer after failure, and we ascribe this to the production process, as we confirm that the creme-heavy side is uniformly oriented within most of the boxes of Oreos. However, cookies in boxes stored under potentially adverse conditions (higher temperature and humidity) show cohesive failure resulting in the creme dividing between wafer halves after failure. Failure mechanics further classify the creme texture as "mushy." Finally, we introduce and validate the design of an open-source, three-dimensionally printed Oreometer powered by rubber bands and coins for encouraging higher precision home studies to contribute new discoveries to this incipient field of study

1st Place Machinery Inc.

What causes temperature humidity chamber to alarm?

Technical Library | 2019-12-12 02:43:44.0

Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.

Symor Instrument Equipment Co.,Ltd

Maintenance and operation of walk-in temperature humidity test chamber

Technical Library | 2019-11-17 22:46:45.0

Overview of walk-in temperature and humidity chamber: It also belongs to environmental test equipment, it tests whether the product can resist high temperature, low temperature, humidity, or the physical and chemical changes produced under extreme conditions, the walk-in temperature and humidity chamber volume is large, the product is placed, or a large object can be placed, such as automobile, new energy, television and liquid crystal screen, etc. How to do the routine maintenance of the walk-in temperature and humidity chamber: 1. The wet gauze basically, if there is no special case, s/b usually changed once in 3 months 2. The water channel shall be regularly cleaned, including water cup, water tank, etc., so as to prevent the water from being blocked,affect the humidity test. 3. It is forbidden to test the flammable and explosive products inside working room. 4. Clean the chamber on a regular basis 2. How to operate walk-in temperature and humidity chamber: The operation method is same as standard temperature humidity test chamber,the controller is 7-inch LCD programmable color screen, you only need to setthe temperature point---test time--how many cycles need to be tested, This can be done automatically, and the machine will stop automatically when it is complete. If there is any problem during the operation, the corresponding problem point will be displayed on the machine control screen. Walk-in temperature and humidity chamber is a must equipment for reliability test of Automobile,Aerospace,Electronic parts,etc,the operation and maintenance are easy,it is teh tear down mahcine,Climatest engineers will be dispatched to do on-site support,for instance,we will finish commissioning,train customers how to operate,maintain,welcome to follow our company facebook page:https://www.facebook.com/Climatechambers

Symor Instrument Equipment Co.,Ltd

Why we need to proceed temperature humidity test?

Technical Library | 2019-10-29 02:55:33.0

For every 10 ℃ increase in temperature, the reaction rate is twice to three times. This means that for every 10 ℃ increase in temperature, the life span of the product will be halved, and when the temperature rises by 20 ℃, the life span of the product will be reduced to 1/4. High temperature will lead to aging, oxidation, evaporation, physical deformation and so on. Low temperature will lead to embrittlement, ice formation, viscosity and solidification degree, loss of mechanical strength, physical shrinkage and so on. When the product is shipped, stored and operated in the environment, it will be endangered. In addition, each product has regulatory and certification requirements, and it is important to evaluate reliability and durability before it is put on the market. In general, according to the IEC60068 test standard, it requires the volume of the laboratory to be at least five times the total volume of the sample under test. Haida constant temperature and humidity box can help you meet this demand. So with the fast developmement of manufacturing industry,test becomes a necessity to see wether the product is able to meet regulated standards in R&D satge,Climatest Symor specializes in handling temperature and humidity,we supply environmental test chamber to China State-owned Research Institutes and laboratories,and obtain excellent reputation from international cllients,our company put much efforts on chamber R&D ,striving to supply best-quality climate simulation equipment and after-sale service. For details,pls visit our official website www.climatechambers.com

Symor Instrument Equipment Co.,Ltd

Factors determine the price of temperature humidity test chamber

Technical Library | 2019-12-16 22:20:55.0

When we were children,our parents always warn us "Do comparison shopping before you buy",why they say like this?this is a very simple truth, for the first deal,we are always cautious, through continuous comparison in order to find out the best quality, service, after-sale and price. This apply to any industry,there are many manufacturers of environmental test equipment. When some customers inquire a temeprature humidity test chamber, they will find a very common problem. Why is the price of the same equipment quoted by the two manufacturers very different? 1, the chamber body process,which effects the exterior case quality,this price has a gap. 2, the components, esp.components of the refrigeration system, is the core value of the temperature humidity test chamber. 3, even if the body and refrigeration components are the same, some prices are different, that is the manufacturer technical level. 4, regional issues, Wuxi,Changzhou, Dongguan, these brands need to know more. 5. after-sales, a powerful manufacturer often with a sound after-sales service dept.. The above are both technical and service, as well as the delivery cost of goods to the local and overseas are different.

Symor Instrument Equipment Co.,Ltd

Notices in the use of temperature and humidity Test Chamber

Technical Library | 2019-05-06 23:04:05.0

The temperature and humidity test chamber simulate the temperature and humidity, so there are a lot of things customers shoud notice in the process of use, although there is detailed instruction when purchasing the equipment. But some users just know how the device works and start using it. This is very easy to cause problems in the use of the equipment, so Symor intends to describe the safety details during the use of temperature and humidity chamber. 1. Before the test, determine if the sample contains flammable and explosive substances to avoid combustion or explosion during the test. Of course, also make sure there is no flammable and explosive material around the test equipment, otherwise it may cause fire and other accidents. 2, Do not open the chamber door to operate during the experiment, or the gas in the studio may cause the operator to burn and so on. 3. At the end of the test or at the time of regular cleaning of the test chamber, power off the equipment to avoid electrocution accidents. Also, when cutting off the equipment power, pull the power cord to pull out the plug, otherwise it may lead to a rupture of the power cord and so on. You can contact manufacturers if there are some places you donnot understand, do not dismantle and repair the temperature and humidity test chamber without authorization, otherwise it may lead to more serious problems.

Symor Instrument Equipment Co.,Ltd

Dust removal in temperature and humidity Test Chamber (2/2)

Technical Library | 2019-05-21 00:21:26.0

Continue to talk about the dust removal from temperature humidity test chamber. Cleaning and maintenance: 1) Pls remove internal impurities inisde chamber before operation. 2) The power distribution room should be cleaned at least once a year, and the dust can be removed by vacuum cleaner. 3) The exterior chamber must also be cleaned more than once a year, which can be wiped with soapy water. Inspection and maintenance of humidifier: The water storage in humidifier should be replaced once a month to ensure clean water quality, humidifying water tray should be cleaned once a month to ensure smooth flow of water. The inspection of over-temperature protector:during the test: If the temperature is over 20 ℃ ~ 30 ℃ than the maximum value setted,the power supply of the heater will stop, the "OVERHEAT" overt-emperature warning light will automatically turn on but the fan is still in operation, if the equipment runs without operator around,the operator should check the over-temperature protector in advance to ensure wether it has been setted properly before start [wet ball over-temperature protector set to 120 ℃].

Symor Instrument Equipment Co.,Ltd

How to fill water into the temperature humidity test chamber? (2/2)

Technical Library | 2019-05-16 02:25:15.0

limatest Symor wants to tell you that humidity is not only the most important thing in the chamber, but also the temperature In order to facilitate customers to add water, our temperature and humidity test chamber is to place the water tank at back of the equipment.Just open the baffle to see the water tank and the water level meter next to the tank,then add enough water to the tank. However, in addition to manual water addition, our temperature and humidity test chamber has equipment that can automatically add water. Only by connecting the water pipe at the water filling port can it be automatically replenished when there is a shortage of water, which is suitable for high humidity test for a long time.

Symor Instrument Equipment Co.,Ltd

How to settle it if there is water existed inside the compressor of temperature humidity chamber?

Technical Library | 2019-05-08 00:04:49.0

It is necessary to know there are some faults that cannot be entirely avoided during the use of temperature and humidity test chamber, but how to deal with them in time is a problem that needs to be paid attention to.Here mainly explain the temperature and humidity test chamber compressor in the reason for the water, and how to deal with it. Reason: water comes from air, because there is always water in the air, known as humidity, which is compressed into supersaturated air and then analyzed to become liquid. The oil comes from the lubrication system of the compressor, possibly because the wear clearance of the mechanism increases, and the lubricating oil will escape into the cylinder. Solution: after the compressor is removed from the temperature and humidity test chamber, with a larger gas storage tank, the oil and water will naturally settle down to the bottom of the jar, and we need to discharge regularly to reduce the oil and water content in the compressed air. Of course, you can also use filters and other things to further reduce the content of oil and water. if you need to know more details about climatic chamber, keep an eye on our website www.climatechambers.com

Symor Instrument Equipment Co.,Ltd

What is UV weathering test chamber

Technical Library | 2019-06-10 22:14:11.0

UV-Lamp Weathering Test Chamber takes fluorescent UV lamps as light source to simulate the UV irradiation in natural light and condensation to conduct accelerated weathering test on the materials, It simulates UV, rain, high temperature, humidity, condensation, darkness and other environmental conditions, combine them together, and carry them out automatically.

Symor Instrument Equipment Co.,Ltd

  1 2 3 Next

humidity temperature searches for Companies, Equipment, Machines, Suppliers & Information

2024 Eptac IPC Certification Training Schedule

Training online, at your facility, or at one of our worldwide training centers"
Potting and Encapsulation Dispensing

High Throughput Reflow Oven
SMT Machines

World's Best Reflow Oven Customizable for Unique Applications
used smt parts china

Nozzles, Feeders, Spare Parts - Siemens, Fuji, Juki, Yamaha, etc...
Assembly Automation Technology

Reflow Soldering Oven & Pressure Curing Oven Manufacturer in India