Technical Library: sense (Page 1 of 2)

Making Sense of Accuracy, Repeatability and Specification for Automated Fluid Dispensing Systems

Technical Library | 2013-11-14 10:43:40.0

Understanding accuracy and repeatability is an important step to analyze fluid dispensing system performance. They can also be prone to misinterpretation when reviewing a product specification. A dispensing motion system can be made to perform better or worse under different operating conditions. This article will explain accuracy and repeatability, and how they can be applied to different specifications. It will also discuss key considerations when interpreting accuracy and repeatability for decision making.

ASYMTEK Products | Nordson Electronics Solutions

A Flexible Front-End for Wearable Electrochemical Sensing

Technical Library | 2022-01-19 17:06:16.0

This work presents the design and the realization of a flexible front-end circuitry for electrochemical sensing with wearable devices. The hardware combines readout circuitry for amperometric and Open Circuit Potential (OCP) measurements. The sensing platforms are dedicated to lactate and lithium detection in sweat, hence allowing the monitoring of athletes under physical effort.

Swiss Federal Institute of Technology Lausanne - Integrated Systems Laboratory (Laboratoire des Systèmes Intégrés – LSI)

SMT Line or Manual PCB Assembly? When Hand Assembly Makes Sense

Technical Library | 2017-12-29 22:38:10.0

Although PCB assembly is a highly automated process, there are times when manual PCB assembly makes sense for prototyping innovative tech products.

Power Design Services

Non‑Invasive Monitoring Of Ph And Oxygen Using Miniaturized Electrochemical Sensors In An Animal Model Of Acute Hypoxia

Technical Library | 2022-01-19 17:50:20.0

pH and oxygen electrochemical sensors were evaluated in a ventilatory hypoxia rabbit model. The ventilator hypoxia protocol included 3 differential phases: basal (100% FiO2), the hypoxia-acidosis period (10% FiO2) and recovery (100% FiO2). Sensors were tested in blood tissue (ex vivo sensing) and in muscular tissue (in vivo sensing). pH electrochemical and oxygen sensors were evaluated on the day of insertion (short-term evaluation) and pH electrochemical sensors were also tested after 5 days of insertion (long-term evaluation). pH and oxygen sensing were registered throughout the ventilatory hypoxia protocol (basal, hypoxia-acidosis, and recovery) and were compared with blood gas metabolites results from carotid artery catheterization (obtained with the EPOC blood analyzer).

Universitat de Barcelona

Printed Electronics for Medical Devices

Technical Library | 2020-11-10 15:50:20.0

As is the case with many other markets where faster, highly capable technologies have resulted in more intelligent processes and products, the medical device sector is also undergoing a "smart" transformation. This has driven the development of medical devices that provide greater access to in-home care and monitoring and faster results for medical professionals, with the overarching benefit of better patient outcomes. Devices applied to the human body that commonly sense

Henkel Electronic Materials

Be Vigilant: It’s a Jungle Out There

Technical Library | 2013-04-12 07:22:40.0

Here Chris talks about the pitfalls, the paucity of safe options for manufacturers seeking rare components, and his exasperation with organisations that appear to shelve common sense at the first sign of a shortage. He shares his ‘no nonsense’ approach to getting things right first time, and explains his thinking in establishing an independent distributor focused exclusively on delivering 100% component integrity.

Vigilant Components

Basics of ASHCROFT Pressure Transmitter - Performance Index, Wiring, Thread Type, Unavoidable Inaccuracies and Mounting

Technical Library | 2021-11-29 01:10:58.0

ASHCROFT pressure transmitter is one of the most commonly used transmitters in industrial applications. It is widely used in a variety of control environments, involving water conservancy and hydropower, railway transportation, intelligent building, production automation, aerospace, military, petrochemical, oil wells, electric power, ships, machine tools and pipelines. ASHCROFT pressure transmitter is an electronic device that senses the pressure signal and converts it into an available output electrical signal according to certain rules.

OKmarts Industrial Parts Mall

Printed Circuit Board (PCB) Technology for Electrochemical Sensors and Sensing Platforms

Technical Library | 2021-02-17 22:13:39.0

The development of various biosensors has revolutionized the healthcare industry by providing rapid and reliable detection capability. Printed circuit board (PCB) technology has a well-established industry widely available around the world. In addition to electronics, this technology has been utilized to fabricate electrical parts, including electrodes for different biological and chemical sensors. High reproducibility achieved through long-lasting standard processes and low-cost resulting from an abundance of competitive manufacturing services makes this fabrication method a prime candidate for patterning electrodes and electrical parts of biosensors. The adoption of this approach in the fabrication of sensing platforms facilitates the integration of electronics and microfluidics with biosensors. In this review paper, the underlying principles and advances of printed board circuit technology are discussed. In addition, an overview of recent advancements in the development of PCB-based biosensors is provided. Finally, the challenges and outlook of PCB-based sensors are elaborated. doi:10.3390/bios10110159

Louisiana State University

Advanced Technologies for Industry – Product Watch Flexible and printed electronics

Technical Library | 2021-07-13 19:51:10.0

Flexible electronics refers to a class of lightweight, flexible and electronic sensing components and electronic devices built on stretchable substrates1 that are used (and can be used) for a broad set of products and applications such as displays and sensors. The most prominent characteristic is that they can bend in contrast to electronic systems built in rigid materials. They are manufactured on flexible plastic substrates, such as polyamide, PEEK2 or transparent conductive polyester films3, or other materials such as paper, textile, or thin glass. The term flexible also refers to the roll-to-roll manufacturing process.

European Commission - Executive Agency for Small and Medium-sized Enterprises (EASME)

Printing and Curing of Conductive Ink Track on Curvature Substrate using Fluid Dispensing System and Oven

Technical Library | 2017-12-21 11:24:05.0

The present work concerns on the use of sensors to monitor the structural health of wind turbine . Conventionally the inspection was made using non-contact sensing during the turbine’s inoperable period hence loss occurred. A real -time monitoring system via embedded wireless sensor is preferred but the sensor could only be implanted using non-contact printing method due to most turbine blade s’ curved surface. Conductive ink associate d with non-contact printing method via fluid dispensing system are proposed since conductive inks are proven stretchable and fluid dispensing system enables printing on various substrates and works well with any materials...

University of Tun Hussein Onn

  1 2 Next

sense searches for Companies, Equipment, Machines, Suppliers & Information

Selective soldering solutions with Jade soldering machine

Reflow Soldering 101 Training Course
2024 Eptac IPC Certification Training Schedule

Software programs for SMT placement and AOI Inspection machines from CAD or Gerber.
thru hole soldering and selective soldering needs

Training online, at your facility, or at one of our worldwide training centers"