Technical Library: cabinet (Page 1 of 2)

DRY BOX DESICCANT STORAGE FOR PCB MANUFACTURING

Technical Library | 2023-09-23 22:31:52.0

Dry boxes can be implemented at various points within the Mfg. environment; for med-long term inventory, or for short term handling on the production floor, and in some cases (with certain conditions) as a process replacement for baking. Bare boards, raw components and partially assembled PCB's can benefit from ultra-low humidity storage.

XDry

When you pull out the nitrogen pipe of nitrogen cabinet

Technical Library | 2019-11-07 03:07:12.0

Many customers who have purchased the nitrogen cabinets have been in the mistaken belief that the air pipe can be pull down hard,so that it can cause the board to be damaged due to the hard pulling of the air pipe, which leads to the replacement of the penetrating board. Now, the following pictures are provided. Please note: Nitrogen cabinet is a optiomal choice for the microelectronics,semiconductor for humidity proof and anti-oxidation purpose,Climatest has put much efforts on the R&D of dry cabinets,as you know,our advangtage is to handle temperature and humidity,since early 1990s,our engineers began to test and research dry cabinet and nitrogen cabinet,all of our manufacturing process strictly follow ISO9001 standard,we supply to international customers for 20 years,if you are still looking for a reliable dry cabinet manufacturer to protect your MSD from moisture related damage,come to visit www.climatechambers.com,we are ready!

Symor Instrument Equipment Co.,Ltd

What is humidity control dry cabinet?

Technical Library | 2019-05-17 01:50:39.0

Dry cabinet is especially designed with fully automatic humidity control to prevent moisture related defects. This cabinet is the optimal storage expert for SMT/BGA/PCB/IC electronic components.Our newly developed design greatly increases dehumidifying system which runs faster and more reliable compare to those traditional dry cabinets. it decreases the defective rate at production line.

Symor Instrument Equipment Co.,Ltd

Evaluation Report Medium Temperature Dry Cabinet

Technical Library | 2024-02-07 18:49:35.0

Report of different drying temperatures

TOTECH Canada N.A Inc

What is usage of Electronic dry cabinet?

Technical Library | 2019-08-19 23:55:20.0

Electronic dry cabinet for MSD storage Humidity is one of the key reasons for rejected products, many manufacturers are taking measures to control the humidity to increase production efficiency and save cost. In semiconductor and electronic industry, the key section of rejected products mostly happen during SMT heating process, Climatest Symor® auto dry cabinet is a superior solution to avoid the cracking. Warranty: two years with lifetime technical support

Symor Instrument Equipment Co.,Ltd

What is the application of moisture proof dry cabinet?

Technical Library | 2019-04-11 05:59:57.0

Are your MSD safely stored? As humidity is found to be one of the key reasons for rejected products, many manufacturers are taking measures to control the humidity to increase their production efficiency and save the cost. In the industries of semi-conductor and electronics, the key section in which the rejected products are most probably to be made is that during the heating process of SMT, the IC(e.g.,PBGA,BGA,or TQFD) is likely to crack and thus cause non-effective welding because of the humidity. Climatest Symor® auto dry cabinet is the best solution to avoid the cracking and non#2;effective welding by dehumidifying the surface of your components. The dry unit can be used for 20 years without replacement,and controller is calibration free within 5 years.We attach dry cabinet application with different humidity range,welcome to download.

Symor Instrument Equipment Co.,Ltd

How to protect your PCB from moisture related damage?

Technical Library | 2019-04-07 22:47:46.0

How to protect your PCB from moisture related damage? J-STD-033 put forward stricter regulation on the MSD exposure environment,when the exposure time exceed the tolerated,the moisture will penetrate into electronics,Moreover, the newest RoHS regulation will rise soldering temperature,the sudden high temperature will lead to expansion and cracking on electronic components. In order to decrease the moisture defect on PCB for the manufacturers in China,Climatest Symor® begin to concentrated on electronic dry cabinet R&D since early 1990s,we specialize in handling temperature and humidity for 20 years,and we provide best solution for PCB storage.

Symor Instrument Equipment Co.,Ltd

MSD in Electronic Assembly

Technical Library | 2023-09-23 22:29:02.0

Moisture trapped within components and PBs presents a serious problem during the fabrication and assembly process. Too much moisture can lead to board failures when it is turned to steam during the reflow process.

Acroname

Drying printed circuit boards

Technical Library | 2024-01-08 18:36:01.0

The following aims lie behind the investigations described: The circuit board is an integrated structure made of metal and plastic. Like most integrated components enclosed in plastic, it absorbs water. When it is rapidly heated as, for example, in soldering technology temperature processes, it is a well known fact that the water will evaporate abruptly, leading to destruction. It is therefore essential that the circuit board be dried before these soldering processes. Circuit board manufacturers are extremely hesitant at providing instructions on drying their circuit boards. Information from the ZVEI [1] should also be regarded critically. The cardinal problem is the high temperature which is recommended for baking. If this is applied, the result is often de-lamination and distortion of the circuit boards. Corrosion and the formation of intermetallic phases of the metallic surfaces are also to be expected. The following investigates whether gentle drying at 45°C or 60°C and at low relative humidity achieves the same result as baking at high temperatures. The industry provides novel dry cabinets which are suitable for rapid drying at relative humidities below one percent.

TOTECH Canada N.A Inc

Handling of Highly-Moisture Sensitive Components - An Analysis of Low-Humidity Containment and Baking Schedules

Technical Library | 2022-09-12 14:07:47.0

Unique component handling issues can arise when an assembly factory uses highly-moisture sensitive surface mount devices (SMDs). This work describes how the distribution of moisture within the molded plastic body of a SMD is an important variable for survivability. JEDEC/IPC [1] moisture level rated packages classified as Levels 4-5a are shown to require additional handling constraints beyond the typical out-of-bag exposure time tracking. Nitrogen or desiccated cabinet containment is shown as a safe and effective means for long-term storage provided the effects of prior out-of-bag exposure conditions are taken into account. Moisture diffusion analyses coupled with experimental verification studies show that time in storage is as important a variable as floor-life exposure for highly-moisture sensitive devices. Improvements in floor-life survivability can be obtained by a handling procedure that includes cyclic storage in low humidity containment. SMDs that have exceeded their floor-life limits are analyzed for proper baking schedules. Optimized baking schedules can be adopted depending on a knowledge of the exposure conditions and the moisture sensitivity level of the device.

Alcatel-Lucent

  1 2 Next

cabinet searches for Companies, Equipment, Machines, Suppliers & Information

Equipment Auction - Eagle Comtronics: Low-Use Electronic Assembly & Machining Facility 2019 Europlacer iineo + Placement Machine  Test & Inspection: Agilent | Tektronix | Mantis Machine Shop: Haas VF3 | Haas SL-20 | Mult. Lathes

Software for SMT placement & AOI - Free Download.
Hot selling SMT spare parts and professional SMT machine solutions

Training online, at your facility, or at one of our worldwide training centers"
2024 Eptac IPC Certification Training Schedule

High Throughput Reflow Oven
SMT feeders

High Resolution Fast Speed Industrial Cameras.