Rohde & Schwarz SMU200A
Model: |
Rohde & Schwarz SMU200A |
Category: |
|
Condition: |
|
Location: |
USA |
Offered by: |
|
Contact Supplier |
Rohde & Schwarz SMU200A
Vector Signal Generator
The R&S SMU200A Vector Signal Generator not only combines up to two independent signal generators in one cabinet of only four height units, it also offers unrivalled RF and baseband characteristics. The generator has been designed to meet all requirements encountered in research and development of modern communication systems as well as in their production.
Key facts:
First RF path from 100 kHz to 2.2/3/4/6 GHz
Optional second RF path from 100 kHz to 2.2/3 GHz
Up to two complete baseband paths
Support of 3GPP LTE FDD and TDD, 3GPP FDD/HSPA/HSPA+, GSM/EDGE/EDGE Evolution, TD-SCDMA, WiMAX and all other important digital standards
2×2 MIMO with realtime fading possible
Two instruments combinable for 2×4 or 4×2 MIMO
Optional fading simulator with up to 40 fading paths
I/Q modulator with 200 MHz RF bandwidth
Optional baseband generator with realtime coder and arbitrary waveform generator
Outstanding RF performance
Options at additional cost:
SMU-B102 = 100 kHz to 2.2 GHz
SMU-B103 = 100 kHz to 3 GHz
SMU-B104 = 100 kHz to 4 GHz
SMU-B106 = 100 kHz to 6 GHz
SMU-B20 = FM/uM Modulator
SMU-B22 = FM/uM Modulator and Enhanced Phase Noise Performance
SMU-B31 = High-Power Output
SMU-B202 = 100 kHz to 2.2 GHz RF Path B
SMU-B203 = 100 kHz to 3 GHz RF Path B
SMU-B36 = High-Power Output RF Path B
SMU-B9 = Baseband Generator with ARB (128 Msample) and Digital Modulation (realtime)
SMU-B10 = Baseband Generator with ARB (64 Msample) and Digital Modulation (realtime)
SMU-B11 = Baseband Generator with ARB (16 Msample) and Digital Modulation (realtime)
SMU-B13 = Baseband Main Module
SMU-B16 = Differential I/Q Output
SMU-B17 = Baseband Input (analog/digital)
SMU-B18 = Digital Baseband Output
SMU-K4 = GSM/EDGE Digital standard
SMU-K42 = 3GPP FDD Digital standard
SMU-K43 = 3GPP Enhanced BS/MS Tests included HSDPA Digital standard
SMU-K44 = GPS Digital standard
SMU-K45 = 3GPP FDD HSUPA Digital standard
SMU-K46 = CDMA2000 Digital standard
SMU-K47 = 1xEV-DO Digital standard
SMU-K48 = IEEE 802.11 (a/b/g) Digital standard
SMU-K49 = IEEE 802.16 Digital standard
SMU-K50 = TD-SCDMA Digital standard
SMU-K51 = TD-SCDMA Enhanced BS/MS Tests Digital standard
SMU-K52 = DVB-H Digital standard
SMU-K53 = DAB/T-DMB Digital standard
SMU-K54 = IEEE 802.11n Digital standard
SMU-K55 = EUTRA/LTE Digital standard
SMU-K56 = XM RADIO Digital standard
SMU-K61 = Multicarrier CW Signal Generation Digital standard
SMU-K65 = Assisted GPS Digital standard - See more at: http://www.testequipmentconnection.com/37512/Rohde_Schwarz_SMU200A.php#sthash.luJkOyhz.dpuf