Agilent N5242A
Model: |
Agilent N5242A |
Category: |
|
Condition: |
|
Location: |
Florida, USA |
Offered by: |
|
Contact Supplier |
Keysight-Agilent N5242A
Base Frequency: 10 MHz Max Frequency: 26.5 GHz
Microwave Network Analyzer
N5242A/200/H85285
N5242A PNA-X Series Microwave Network Analyzer, 10 MHz to 26.5 GHz
The Nonlinear Vector Network Analyzer (NVNA) provides industry-leading performance, accuracy, and configurability to simplify test setups and provide detailed insight into designing nonlinear components. The N5242A with NVNA accurately measures and displays the nonlinear behavior of the device under test to deterministically design components, modules and systems.
Features:
Measure amplitude and phase of the full device spectra, traceable to National Institute of Science and Technology (NIST)
10 MHz to 26.5 GHz of vector corrected bandwidth for time domain waveforms of voltage and currents of DUTs
Gain new insight into your component behavior using X-parameters – the new S-parameters for nonlinear measurements
Use X-parameters in Agilent’s Advanced Design System (ADS) for fast, accurate nonlinear simulation and design
Based on standard, powerful PNA-X and then adding nonlinear features and capability
Options at Additional Cost:
008 - Pulsed-RF measurements
010 - Time-domain measurements
020 - Add IF inputs
021 - Add pulse modulator to internal first source
022 - Add pulse modulator to internal second source
025 - Add four internal pulse generators
028 - Noise figure measurements using standard receivers
029 - Fully-corrected noise-figure measurements to 26.5 GHz
080 - Frequency offset measurements
082 - Scalar calibrated converter measurements
083 - Vector and scalar calibrated converter measurements
084 - Embedded LO measurements
086 - Gain compression application
087 - Intermodulation distortion measurements
088 - Source phase control
118 - Fast CW mode
1A7 - ISO 17025 compliant calibration
1CM - Rack mount kit for installation without handles
1CP - Rack mount kit for installation with handles
200 - 2 ports, single source
219 - Add extended power range and bias-tees to 2 port analyzer
224 - Add internal second source, combiner and mechanical switches to 2-port analyzer
301 - Application for use with standard CalPods
302 - Application for use with temperature-characterized CalPods
400 - 4 ports, dual source
419 - Add extended power range and bias-tees to 4 port analyzer
423 - Add internal combiner and mechanical switches to 4-port analyzer
460 - Integrated true-mode stimulus application
510 - Nonlinear Component Characterization
514 - Nonlinear X-Parameters
518 - Nonlinear Pulse Envelope Domain
520 - Arbitrary load impedance X-parameters
551 - N-port calibrated measurements
629 - Noise figure accessories
897 - Built-in performance test software for Agilent inclusive calibration, perpetual license
898 - Built-in performance test software for standards compliant calibration, perpetual license
A6J - ANSI Z540 compliant calibration
H08 - Pulsed - RF measurments
H85 - Removes bias tees between source attenuators and test port couplers
UK6 - Commercial calibration certificate with test data
- See more at: https://www.testequipmentconnection.com/39560/Agilent_N5242A.php#sthash.KykTwzoM.dpuf