Full Site - : humiseal 1b31 acrylic coating side effects (Page 2 of 4)

Acrylic conformal coat cure test method

Electronics Forum | Wed Feb 28 20:10:08 EST 2001 | mhunter

Checked the archives with no luck. Anyone have a reliable test method of verifying acrylic conformal coat cure. Using Humiseal 1B31 mixed with approximately 30% solvent, spraying with a Nordson. Thanks in advance.

Acrylic conformal coat cure test method

Electronics Forum | Wed Feb 28 20:16:26 EST 2001 | mhunter

Checked the archives with no luck. Anyone have a reliable test method of verifying acrylic conformal coat cure. Using Humiseal 1B31 mixed with approximately 30% solvent, spraying with a Nordson. Thanks in advance.

Acrylic comformal coat on PCB

Electronics Forum | Thu May 02 14:07:53 EDT 2013 | duso02

I would suggest lowering the viscosity even more. Humiseal even sells 1B31 pre-mixed specifically for spray machines and the highest they go is 65cps.

Urethane/Acrylic thru same machine

Electronics Forum | Thu Sep 06 15:36:27 EDT 2007 | kpm135

My company recently aquired an asymtek coating machine and I have been using Humiseal 1B31, an acrylic coating, in it to coat all the boards given to me. They have now come to me and asked if it is possible to run Humiseal 1A33, a urethane coating, t

AR vs. UR

Electronics Forum | Wed Mar 24 15:04:05 EST 1999 | Greg Curler

I am looking into replacing another business division's Acrylic coating process with our Urethane coating process. Unfortunately, MIL-I-46068 doesn't differentiate AR/UR's performance, and the MFR data sheets don't match up at all (they each spec di

Re: AR vs. UR

Electronics Forum | Wed Mar 24 21:40:05 EST 1999 | Dave F

| I am looking into replacing another business division's Acrylic coating process with our Urethane coating process. Unfortunately, MIL-I-46068 doesn't differentiate AR/UR's performance, and the MFR data sheets don't match up at all (they each spec

Acrylic Coating De-Wetting?

Electronics Forum | Tue Jul 25 16:08:52 EDT 2017 | dontfeedphils

I'm currently working on bringing a manual coating process/workcenter online and my QA team is giving me some grief. For background, we're using Humiseal 1B31 thinned with thinner 521, mixed at 1:1 by volume. Spraying through a Binks HVLP with 10 P

Conformal Coating Room

Electronics Forum | Tue Jul 31 10:16:59 EDT 2012 | silverbullet

We are in the process of revamping our conformal coating room. Presently, we have a C-740 Nordson Asymtek coating machine that sprays most of our boards with Dow Corning 2577. We are spending a lot of time masking boards and are thinking of upgrading

Re: AR vs. UR

Electronics Forum | Thu Mar 25 19:19:08 EST 1999 | Graham Naisbitt

| I am looking into replacing another business division's Acrylic coating process with our Urethane coating process. Unfortunately, MIL-I-46068 doesn't differentiate AR/UR's performance, and the MFR data sheets don't match up at all (they each spec

Re: AR vs. UR

Electronics Forum | Fri Mar 26 13:02:18 EST 1999 | Scott McKee

Sorry, in the following message I'm agreeing with Graham - not Greg... | | I am looking into replacing another business division's Acrylic coating process with our Urethane coating process. Unfortunately, MIL-I-46068 doesn't differentiate AR/UR's p


humiseal 1b31 acrylic coating side effects searches for Companies, Equipment, Machines, Suppliers & Information