Quad QSV-1

Electronics Forum | Wed Apr 08 14:41:35 EDT 2015 | kevinb

I have a Quad QSV-1. When I was teaching the fiducials, an error came up on the screen. ABNORMAL PROGRAM TERMINATION came up. It might have read something different but this was close. It then closed out of the quad program and went to the window

Quad IVc Fiducial Alignment

Electronics Forum | Mon Jan 21 08:26:45 EST 2013 | ngineer

Bobpan, Thanks for the reply. I have been using Tep Vision, I'll see whether I was using GOTO 1 or 0, it may have been 0. I am running from central controller, and am doing a download database from the database utilities when making changes on

Check out a new Q

Electronics Forum | Wed Nov 11 06:59:20 EST 1998 | Jim Mitchell

Scott - Good to see things are going well for you. With regard to your comments, Quad has introduced a complete line of Semi-conductor/APT machines (Q Series) that support both SMT and Semi-conductor applications. The machines were introduced in 19

Re: Quad IIc, Autoprogram

Electronics Forum | Tue Jul 25 18:58:10 EDT 2000 | Bob Miklosey

I am very familiar with AutoProgram and understand the default import formats for the software. AutoProgram wants a centroid file containing part number, ref des., X, Y, and theta. AutoProgram will not directly import an ASCII cad file. However, Ci

Autoprogram 5.31 Manual for Quad IIc

Electronics Forum | Wed Oct 08 14:55:50 EDT 2008 | leemeyer

In the teach menu of Central controller and under Teach Board Fiducials there should be 6 options. Turn on Global Fiducial Correction by putting a Y in the box. Make sure all others including "Fiducial Data from Autoprogram" have an N in the box. Use

Fiducial Recognition

Electronics Forum | Thu Jun 14 20:54:57 EDT 2012 | deanm

We have a Quad QSV-1 and have had some trouble with it reading 0.040" fiducials. Our work is very low volume so we just manually spot the ones it can't read. We do not clean the fiducials. Instead we increased the fiducial size to 0.060" and it has b

Quad 2C ICOS Error

Electronics Forum | Fri Nov 18 17:10:23 EST 2011 | gosswald

1. What version ap and central controller? AP 5.31 CC 7.54 2. What version of windows? Windows 95 3. What size are your vision models? 50 mil circle 150 mil search area. 4. What options are selected in teach fiducials......globabl fiducial cor

Autoprogram 5.31 Manual for Quad IIc

Electronics Forum | Wed Oct 08 12:49:37 EDT 2008 | leemeyer

When in the fiducial teach screen check to see if the "Fiducial Data from Autoprogram" box is checked. If this program was not generated from Autoprogram this box should not be checked.

Autoprogram 5.31 Manual for Quad IIc

Electronics Forum | Wed Oct 08 14:20:34 EDT 2008 | sambolian

I only have 'Y' in the "Global Fiducial Correction" box , but it still gives me the error of "Fiducials not taught". Any more suggestions?

Re: Check out a new Q

Electronics Forum | Thu Nov 12 04:40:03 EST 1998 | Galen

| Scott - Good to see things are going well for you. With regard to your comments, Quad has introduced a complete line of Semi-conductor/APT machines (Q Series) that support both SMT and Semi-conductor applications. The machines were introduced in