PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic3004&OB=ASC.html
? Because right now what I was taught for SMD BGA footprints/Non-collapsing is that instead of making the pad size larger we are following the calculation for Collapsing ball and making our pad size smaller. Instead of using
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic249&OB=ASC.html
. This indicates an error or warning. Could the offended rule be highlighted in yellow? I see in Calculation the "Side Dimension trimmed to maintain clearance
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/bga-pad-size_topic3004.html
? Because right now what I was taught for SMD BGA footprints/Non-collapsing is that instead of making the pad size larger we are following the calculation for Collapsing ball and making our pad size smaller. Instead of using
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/bga-pad-size_topic3004_post11995.html
? Because right now what I was taught for SMD BGA footprints/Non-collapsing is that instead of making the pad size larger we are following the calculation for Collapsing ball and making our pad size smaller. Instead of using
PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/topic923&OB=DESC.html
..." box you're overriding the calculation and forcing the use of whatever values are entered in each textbox adjacent to the referenced dimension
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic923&OB=ASC.html
. As soon as you check the 'Use Mfr's recommended..." box you're overriding the calculation and forcing the use of whatever values are entered in each textbox adjacent to the referenced dimension
Lewis & Clark | https://www.lewis-clark.com/product-tag/ge/
: BGA Analysis Wire Sweep Calculation Voiding Calculation Automatic Positioning Control 160kV Nanofocus X-ray Tube OVHM- Oblique View at Highest Magnification Rotary Table-Rotates 360
PCB Libraries, Inc. | https://www.pcblibraries.com/Forum/smt-terminal-size-shape-vs-pad-size-shape_topic2146.html
. V2018 FP Designer have much more flexibility with irregular shape pads and some new features, but SMT pad size calculation should be done in the Calculator and then moved to FP Designer
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/smt-terminal-size-shape-vs-pad-size-shape_topic2146.html
. V2018 FP Designer have much more flexibility with irregular shape pads and some new features, but SMT pad size calculation should be done in the Calculator and then moved to FP Designer
PCB Libraries, Inc. | https://www.pcblibraries.com/forum/topic2146&OB=ASC.html
. V2018 FP Designer have much more flexibility with irregular shape pads and some new features, but SMT pad size calculation should be done in the Calculator and then moved to FP Designer