Industry Directory | Consultant / Service Provider / Equipment Dealer / Broker / Auctions / Manufacturer / Manufacturer's Representative
Main Products: 1. Original new and Original Used SMT/AI Spare Parts. 2. SMT Equipments And Related Machine( Loader/Unloader,SMT Calibration, SMT Feeder Carts,Conveyer etc.) 3. Maintenace and Repair Service
Systronix, Inc. is an industry leader in the supply of electronic manufacturing services. We provide a broad range of services to leading companies in industries that require high tech, high quality and highly reliable electronics.
New Equipment | Curing Equipment
Heller 788 In-line, Continuous Cure, Vertical Format Oven This elevator format oven utilizes vertical space to accomodate curing applications of up to 4 hours while only occupying 96" (2.5m) of floorspace. Perfect for underfill and encapsulant.
Jetting Simplified Jetting pumps are excellent for dispensing small volumes of fluid at high rates of speed. The NCM5000 simplifies jetting to its basic elements - this means easy set up, cleaning, and maintenance for you. The drive system is design
Used SMT Equipment | Board Cleaners
Aqueous Technologies Batch Cleaner For Sale Excellent Running Condition Aqueous Technologies Model: Trident - CLO Serial Number: 9356 Year 2014-2015 Type: PC Board De-fluxing Cleaner aSPC Software Stainless Steel Wash Chamber Touch Scree
Used SMT Equipment | General Purpose Test & Measurement
Very Nice Thermotron Test Chamber For Sale Thermotron Model Number: SE-600-6-6 Serial Number: 32134 Allen Bradley 1305 Controller Interior Dimensions: 40" x 26.25" x 34" Temperature Range: -70C to 180C Cascade Compressor System Temperature
Industry News | 2016-06-27 14:59:09.0
GPD Global introduces the NEW TempView Thermal Imaging System that ensures the success of heated dispensing processes like Underfill, Encapsulations, Dam and Fill, and more. The TempView Thermal Imaging System monitors the temperature of the entire substrate for complete heat profile characterization. Regions of the product may be selected for monitoring during the heating process. Now you can accurately monitor temperature of specific devices to be sure they are up to temperature before starting a process.
Industry News | 2017-04-11 21:19:32.0
GPD Global offers versatile large format inline dispensing systems and stand-alone liquid dispense technologies for maximizing product yield. This is the largest standard PCB dispensing system platform in the industry.
Technical Library | 2019-12-12 02:43:44.0
Today we discuss the reason that causes temperature humidity chamber to alarm,In most cases, the equipment alarm is caused by the improper operation in the process of use, which mainly includes following reasons:that are refrigeration system, temperature system and circulating system. First, Refrigeration system 1, refrigeration compressor overpressure alarm. If the refrigerant pressure exceeds the set value, it will stop and alarm at the same time. At this time, the fault must be eliminated and then manually reset. 2, short phase power supply, phase sequence alarm. When the external power supply of the equipment is out of phase or the phase sequence is changed, it will stop and alarm at the same time. 3. The circulating cooling water is short of water to alarm. When the water pressure of the cooling circulating water system is insufficient, it will stop and alarm at the same time, and it must wait for the fault to be eliminated and reset at the same time before it could run normally. 4, refrigeration compressor overheating alarm. When the coil of the compressor is overheated and the power supply of the line is not normal, it will stop and alarm at the same time. Second, Temperature system 1, the overtemperature alarm in the chamber. The sensors in the channel and the sample area are equipped with overtemperature protection devices, and there are also overtemperature protecter on the control panel. When the temperature in the working chamber exceeds the setting value on the controller, it will stop and alarm. 2. sample overtemperature protection. When the temperature in the sample area exceeds the protection temperature set by the controller, it will stop and alarm at the same time. The overtemperature protection of the sample is divided into upper limit protection and lower limit protection, which can be set according to the demand, Third,Circulating system 1. The alarm is caused by the overheating of the circulating fan. When the coil of the fan is over-heated, the alarm will be stopped at the same time. 2. The fan over-current alarm. When the current of the fan exceeds the allowable value, the alarm is stopped at the same time, and the normal operation can only be carried out after the fault maintenance of the overcurrent is completed. This is what we talk about today,if you have more questions,let us know.
Technical Library | 2019-05-21 00:21:26.0
Continue to talk about the dust removal from temperature humidity test chamber. Cleaning and maintenance: 1) Pls remove internal impurities inisde chamber before operation. 2) The power distribution room should be cleaned at least once a year, and the dust can be removed by vacuum cleaner. 3) The exterior chamber must also be cleaned more than once a year, which can be wiped with soapy water. Inspection and maintenance of humidifier: The water storage in humidifier should be replaced once a month to ensure clean water quality, humidifying water tray should be cleaned once a month to ensure smooth flow of water. The inspection of over-temperature protector:during the test: If the temperature is over 20 ℃ ~ 30 ℃ than the maximum value setted,the power supply of the heater will stop, the "OVERHEAT" overt-emperature warning light will automatically turn on but the fan is still in operation, if the equipment runs without operator around,the operator should check the over-temperature protector in advance to ensure wether it has been setted properly before start [wet ball over-temperature protector set to 120 ℃].
This elevator format oven utilizes vertical space to accomodate curing applications of up to 4 hours while only occupying 96" (2.5m) of floorspace. Perfect for underfill and encapsulant.
Jetting Simplified Jetting pumps are excellent for dispensing small volumes of fluid at high rates of speed. The NCM5000 simplifies jetting to its basic elements - this means easy set up, cleaning, and maintenance for you. The drive system is design
Events Calendar | Mon Sep 29 18:30:00 UTC 2025 - Tue Sep 30 18:30:00 UTC 2025 | San Diego, California USA
YINCAE Showcases High-Performance Materials at IMAPS 2025
Career Center | New Castle, Pennsylvania USA | Production
Surface Mount Tech - Printed Circuit Board (PCB) Summary: **All applicants must be familiar with: Quad 4C equipment*** Will be responsible for Surface Mount Parts and Screen Printing Other responsibilities may include: Moves controls to activate
Career Center | Norcross, Georgia USA | Production
Solder Technician Reports to: Supervisor Responsibilities: 1) Melts and applies solder along adjoining edges of workpieces to solder joints, using soldering iron, gas torch, or electric-ultrasonic equipment. 2) Grinds, cuts, buffs, or bends edge
Career Center | , | Engineering,Technical Support
COMPETENCIES & SKILLS : Proficient in SMT chip Mounters and IC/Flip chip Placers like Assembleon, Panasonic, Yamaha & etc. Experienced in handling Screen Printers like Minami, Dek, Panasonic and semi-automatic Printers. Expert in Camalot
Career Center | Littleton, CO USA | Production
Possess 18 years relevant work experience in manual/Auto bonding on Micro-Electronic & RF to support new product development in R&D Lab in defense & commercial sectors. Have an advanced soldering skill in both Through-Hole/SMT, and J-STD-001 cert
| http://etasmt.com/te_news_bulletin/2020-05-04/15961.chtml
. The temperature of the reflow soldering oven zones is set relatively high, so that the temperature in the furnace rises rapidly to the peak temperature
| https://www.feedersupplier.com/sale-13119504-7ch-channel-pcb-loader-unloader-kic-x5-temperature-curve-tester.html
7CH Channel PCB Loader Unloader KIC X5 Temperature Curve Tester Leave a Message We will call you back soon! Your message must be between 20-3,000 characters