Assessing the Effectiveness of I/O Stencil Aperture Modifications on BTC Void Reduction

Technical Library | 2018-09-26 20:33:26.0

Bottom terminated components, or BTCs, have been rapidly incorporated into PCB designs because of their low cost, small footprint and overall reliability. The combination of leadless terminations with underside ground/thermal pads have presented a multitude of challenges to PCB assemblers, including tilting, poor solder fillet formation, difficult inspection and – most notably – center pad voiding. Voids in large SMT solder joints can be difficult to predict and control due to the variety of input variables that can influence their formation. Solder paste chemistries, PCB final finishes, and reflow profiles and atmospheres have all been scrutinized, and their effects well documented. Additionally, many of the published center pad voiding studies have focused on optimizing center pad footprint and stencil aperture designs. This study focuses on I/O pad stencil modifications rather than center pad modifications. It shows a no-cost, easily implemented I/O design guideline that can be deployed to consistently and repeatedly reduce void formation on BTC-style packages.

AIM Solder

Noise Fault Detection of High Low Temperature Test Chamber(Climatic chamber)

Technical Library | 2019-04-11 06:04:49.0

With the development of science and technology, the climatic chamber quality has been improved, and the failure rate is reduced, but there still have the failure probability.today we introduce what are the mian factors for big noise high low temperature test chamber: 1.External factors: the bottom angle is uneven, the ground is uneven, adjust the bottom angle, ensure the equipment is in a horizontal position; 2.The equipment is touched other objects or pushed against the wall,pls remove the objects and keep a certain distance from the wall. 3.Compressor noise:check whether the compressor collides with the pipeline,and evaporator dish is loose or not. 4.Check whether compressor shock absorbers are aging and replace them. 5.Solenoid valve noise: solenoid valve reversing caue loud sound, pls add damping glue, if no effect, need to replace solenoid valve. If there is AC noise, need to replace the power board. 6.Check wether the fan or the fan string shaft make noise,whether the fan blades are touched and deformed, whether the fan is fixed or not, pls adjust accordingly or add the rubber pad. If further technical questions,contact us without hesitation!---Climtest Symor® technical team

Symor Instrument Equipment Co.,Ltd

  1  

ground pad searches for Companies, Equipment, Machines, Suppliers & Information