The working principle of IPX9K Rain Test Chamber

Technical Library | 2019-04-18 21:53:04.0

IPX9K Rain Spray Test Chamber(high Pressure high temperature water jet) simulates the use of pressure washer steam cleaning onto the enclosure, It is recognised as the harshest of all ingress protection tests. However the requirement is becoming more prevalent across many industries. Test method for IPX9K : Make sure the water temperature inside the water tank +80°C, water flow rate with 14L-16L per min, water pressure: 8000 Kpa -10000 Kpa (80–100 bar) at distance of 100mm~ 150mm, The test duration is 30 seconds in each of 4 angles, total spray testing time is 2 minutes. IPX9 rain test chamber applicable standards: IEC 60529 – Degrees of protection provided by enclosures (IP Code).Here is working principle in picture.

Symor Instrument Equipment Co.,Ltd

Divergence in Test Results Using IPC Standard SIR and Ionic Contamination Measurements

Technical Library | 2017-07-13 16:16:27.0

Controlled humidity and temperature controlled surface insulation resistance (SIR) measurements of flux covered test vehicles, subject to a direct current (D.C.) bias voltage are recognized by a number of global standards organizations as the preferred method to determine if no clean solder paste and wave soldering flux residues are suitable for reliable electronic assemblies. The IPC, Japanese Industry Standard (JIS), Deutsches Institut fur Normung (DIN) and International Electrical Commission (IEC) all have industry reviewed standards using similar variations of this measurement. (...) This study will compare the results from testing two solder pastes using the IPC-J-STD-004B, IPC TM-650 2.6.3.7 surface insulation resistance test, and IPC TM-650 2.3.25 in an attempt to investigate the correlation of ROSE methods as predictors of electronic assembly electrical reliability.

Alpha Assembly Solutions

Ingress Protection (IP) test for electronic enclosure test

Technical Library | 2019-04-07 23:34:10.0

Ingress Protection Test Chamber is used to determine the protection degree of product enclosures,the protection level provided by the enclosure is called IP code,our IP test chamber compeletely follow the standard IEC60529 and others. IP protection grade is an important index of electrical equipment safety protection. Protective-grade systems such as ip, which provide a method of classifying products in terms of dust-proof, waterproof and anti-collision levels of electrical equipment and packaging, which have been recognized by most European countries, as drafted by the International Electrotechnical Association (iec (international electro technical commission). And announced in ied529 (bs en 60529 / 1992) outer packing protection grade (ip code). The level of protection is expressed in terms of IP followed by two numbers, which are used to define the level of protection. The first number indicates the extent of the equipment‘s resistance to dust, or the degree to which people are protected from harm in sealed environments. I represents a level that prevents solid foreign matter from entering, with a maximum level of 6; The second number indicates the extent to which the equipment is waterproof. P represents the level of protection against influent and the highest level is 8. Such as the protection level of the motor ip65. Contact electrical equipment protection and external material protection level (first digit) Electrical equipment waterproof protection level (second digit) . IP is the international code used to identify the protection grade ip grade consists of two numbers, the first number for dust, and the second number for waterproof, the larger the number means the better protection level.

Symor Instrument Equipment Co.,Ltd

Ultrathin Fluoropolymer Coatings to Mitigate Damage of Printed Circuit Boards Due to Environmental Exposure

Technical Library | 2016-05-19 16:03:37.0

As consumers become more reliant on their handheld electronic devices and take them into new environments, devices are increasingly exposed to situations that can cause failure. In response, the electronics industry is making these devices more resistant to environmental exposures. Printed circuit board assemblies, handheld devices and wearables can benefit from a protective conformal coating to minimize device failures by providing a barrier to environmental exposure and contamination. Traditional conformal coatings can be applied very thick and often require thermal or UV curing steps that add extra cost and processing time compared to alternative technologies. These coatings, due to their thickness, commonly require time and effort to mask connectors in order to permit electrical conductivity. Ultra-thin fluorochemical coatings, however, can provide excellent protection, are thin enough to not necessarily require component masking and do not necessarily require curing. In this work, ultra-thin fluoropolymer coatings were tested by internal and industry approved test methods, such as IEC (ingress protection), IPC (conformal coating qualification), and ASTM (flowers-of-sulfur exposure), to determine whether this level of protection and process ease was possible.

3M Company

How does IPX9K Rain Test Chamber Works?

Technical Library | 2019-05-08 01:46:32.0

IPX9K Rain Spray Test Chamber(high Pressure high temperature water jet) simulates the use of pressure washer steam cleaning onto the enclosure, It is recognised as the harshest of all ingress protection tests. However the requirement is becoming more prevalent across many industries. Test method for IPX9K : Make sure the water temperature inside the water tank +80°C, water flow rate with 14L-16L per min, water pressure: 8000 Kpa -10000 Kpa (80–100 bar) at distance of 100mm~ 150mm, The test duration is 30 seconds in each of 4 angles, total spray testing time is 2 minutes. IPX9K rain test chamber applicable standards: IEC 60529 – Degrees of protection provided by enclosures (IP Code).Here is working principle in picture. Application: It is mainly suitable for testing the performance of shell and seal of electrical and electronic parts, automobile parts and seals under the condition of dripping rain to prevent Rain Water from permeating or working after drizzling.

Symor Instrument Equipment Co.,Ltd

Why we need to proceed temperature humidity test?

Technical Library | 2019-10-29 02:55:33.0

For every 10 ℃ increase in temperature, the reaction rate is twice to three times. This means that for every 10 ℃ increase in temperature, the life span of the product will be halved, and when the temperature rises by 20 ℃, the life span of the product will be reduced to 1/4. High temperature will lead to aging, oxidation, evaporation, physical deformation and so on. Low temperature will lead to embrittlement, ice formation, viscosity and solidification degree, loss of mechanical strength, physical shrinkage and so on. When the product is shipped, stored and operated in the environment, it will be endangered. In addition, each product has regulatory and certification requirements, and it is important to evaluate reliability and durability before it is put on the market. In general, according to the IEC60068 test standard, it requires the volume of the laboratory to be at least five times the total volume of the sample under test. Haida constant temperature and humidity box can help you meet this demand. So with the fast developmement of manufacturing industry,test becomes a necessity to see wether the product is able to meet regulated standards in R&D satge,Climatest Symor specializes in handling temperature and humidity,we supply environmental test chamber to China State-owned Research Institutes and laboratories,and obtain excellent reputation from international cllients,our company put much efforts on chamber R&D ,striving to supply best-quality climate simulation equipment and after-sale service. For details,pls visit our official website www.climatechambers.com

Symor Instrument Equipment Co.,Ltd

Difference between Neutral and Acid Salt Spray Corrosion Test

Technical Library | 2019-12-13 00:39:29.0

Salt spray corrosion chamber can test the ability of material and its protective layer to resist salt mist corrosion, or compare the process quality of similar protective layers, at the same time; this equipment is suitable for parts, electronic components, protective layer of metal material and other industrial products. Salt spray test is divided into neutral and acid test. What is the difference between neutral and acid in salt spray test? First, the temperature applied in the test method is different: Neutral test: a. Laboratory:35°C ±1°C, b. Saturated air drums:47°C ±1°C Acid test: a. Laboratory:50°C ±1°C, b. Saturated air drums:63°C ±1°C Second, the production material is different,neutral test chamber adoptes the traditional PVC plates, acid test chamber asopts PP sheet,which is more high temperature resistance and suits strong acid test. Third. Different test methods satisfied Neutral salt spray chamber according to GB/T 2423.17-2008, GB/T 2423.18-2000, salt spray test method and GB/T 10125-1997, GB/T 10587-2006, GB10593.2-1990, GB/T 1765-1979, GB/T 1771-2007, GB/T 12967.388, GB/T 1705.8-2008, etc. In addition to the test methods specified in the national standard, acid salt spray chamber also needs to expand the standard setting such as IEC,MIL,DIN,ASTM,IS,CNS. Last, Comparison of neutral test solutions China: NaCI distilled water solution NaCI mass concentration (50 ±5) g ≤ l pH value 6.5 ≤ 7.2 United States: distilled water solution NaCI mass concentration 5% ±1% pH value 6.5 ≤ 7.2 Germany: NaCI distilled water solution NaCI mass concentration (50 ±5) g ≤ l pH value 6.5 ≤ 7.2 Japan: NaCI distilled water solution NaCI mass concentration 5% ±1% pH pH value 6.5 ~ 7.2 France: NaCI distilled water solution NaCI mass concentration 5% pH 6.5 ≤ 7.2 https://climatechambers.com/articles&latestnews/difference-between-neutral-and-acid-salt-spray-corrosion-test.html

Symor Instrument Equipment Co.,Ltd

  1  

iec searches for Companies, Equipment, Machines, Suppliers & Information

Selective soldering solutions with Jade soldering machine

Have you found a solution to REDUCE DISPENSE REWORK? Your answer is here.
Selective soldering solutions with Jade soldering machine

Benchtop Fluid Dispenser
Equipment Auction - Eagle Comtronics: Low-Use Electronic Assembly & Machining Facility 2019 Europlacer iineo + Placement Machine  Test & Inspection: Agilent | Tektronix | Mantis Machine Shop: Haas VF3 | Haas SL-20 | Mult. Lathes

Best Reflow Oven
PCB separator