Electronics Forum | Wed Oct 24 00:36:59 EDT 2018 | filipblad
I've checked the locks in the service program and the solenoids move when told to.. also I can see them opening when going to pick up a tool..
Electronics Forum | Wed Oct 24 07:33:44 EDT 2018 | tech1
when the machine initiates the last move it does is in the Z axis. If memory serves me, during the last Z move it drives down and measures the stroke, if the lower solenoid is not fully retracted the axis measures the wrong travel limits. Hopefully t
Electronics Forum | Wed Oct 24 08:26:46 EDT 2018 | filipblad
You mean that the problem could be that the solenoid retracts but not all the way?
Electronics Forum | Wed Oct 24 09:25:23 EDT 2018 | filipblad
The solenoids seem to work properly and there are no problems when initiating the Z-axis
Electronics Forum | Wed Oct 24 09:26:39 EDT 2018 | tech1
Correct, if the Z comes into contact on it's downward stroke during init this can cause the problem you are seeing
Electronics Forum | Wed Oct 24 09:31:26 EDT 2018 | tech1
It could be the indicators inside the Z head, have you tried cleaning them? Can you post an image of the error that appears on the monitor?
Electronics Forum | Wed Oct 24 10:02:17 EDT 2018 | tech1
That error points to a hardware issue. When it fails does it ask you to insert a tool manually?
Electronics Forum | Fri Jan 23 14:26:25 EST 1998 | Greg Rust
Has anyone experianced Core Dump errors with their MYDATA TP9? My machine (2/96) has 26 million placements and my operators have recorded 253 core dumps in 1996, 238 in 1997, and 18 in January of 1998. We run one job on the machine, period. Our prev
Electronics Forum | Wed Sep 16 14:04:33 EDT 2015 | adventurelights
Hi guys, Recently got an error message when initiating hardware on a Mydata TP9-UFP. Message is: Theta/2: Lower end point not repeatable. Reinitiating fails at message. Haven't seen this message before. Any idea what it could be as production is hal
Electronics Forum | Wed Sep 30 06:25:14 EDT 2015 | strongbyte
I am looking to buy a Flexible magazine for a Mydata TP9-UFP I have seen both TMCFlex and TMDFlex magazines available, does anybody know the difference between the two and whether they are compatible with my machine. I spoke to a Mycronic engineer