Full Site - : dek 265 backup program (Page 3 of 13)

DEK 265

Electronics Forum | Wed Jan 06 15:25:35 EST 2010 | wolverine

Any help would be appreciated We have a DEK 265 Screener that has been showing symtoms of a bad power supply. Is there a way to back up the hard drive and is an executive program needed in case the machine totally dies. Dave

DEK 265

Electronics Forum | Wed Feb 03 15:57:18 EST 2010 | baildl632

We have a DEK 265 also. It may be the PNOZ (relays in a box) or the "in rush" capacitors "leaking" or "opening" causing your power supply symptoms. Went through something that sounds similar to your description of "power supply" problems. Your best o

Dek 265

Electronics Forum | Wed May 03 08:43:51 EDT 2006 | Mark Fick

I have a DEK 265 with error code: motor comms failure.card 0, Axis123 fatal error-reinitialize machine during machine boost up I replaced new card 0 and still get the same error.I have tried to load the mint program but I cannot get program to abort

DEK 265 GSX Software*

Electronics Forum | Sat Jun 08 13:05:01 EDT 2013 | stanb

Does anyone have software discs for a 1999 DEK 265 GSX? We had a disc failure without a backup.

DEK 265 GSX missprint

Electronics Forum | Tue Mar 29 14:43:50 EDT 2022 | padawanlinuxero

Hi! Looks likely you have a calibration problem with the vision system, since is a 265 if possible try to restore a backup on floppy if not rerun the calibration procedure

DEK 265 GSX missprint

Electronics Forum | Tue Mar 22 16:12:30 EDT 2022 | dekhead

Most likely corrupted vision calibration. Reload backup calibration from floppy (of available), rerun calibration ("Calibrate Vision")

DEK 265 vision alignment...

Electronics Forum | Thu Feb 13 10:38:33 EST 2003 | vortex

While trying to develop new programs for our DEK Horizon 265 we are forced to use pads as vision alignments due to lack of real fiducals, thanks engineering. My question is, Is there any way to narrow the search window when performing a locate fiduca

DEK 265 GSX

Electronics Forum | Fri Aug 24 02:40:52 EDT 2018 | bukas

first check fuses in Y1 case. thats where EuroSYS cards are, and message you get tells you that cards can not communicate with main processing board in Y3 case via RS485. after that check cables and connectors. there are 4 EuroSYS cards in Y1 case, t

Re: DEK 265 opinions needed please

Electronics Forum | Fri May 26 13:16:53 EDT 2000 | Todd

I have worked with MPM and GSP (fuji) and the DEK. I have had the least problems with the DEK. Kept having software issues with the MPM although I have heard some having good experiences. We used the GSP for the through hole but needed new vaccum

DEK 265 to DEK Horizon 2 question

Electronics Forum | Tue Jan 21 08:49:42 EST 2020 | emeto

I am sure you can upgrade it with DEK and it should not be so expensive. You can also ask them the price of the auto system. This is an arm(controlled by cylinder I think) and software to control it. This one moves the stencil in place when you load