Industry Directory | Manufacturer
DriSteem provides reliable and efficient humidity control, evaporative cooling, and water treatment solutions for commercial and industrial applications.
Industry Directory | Manufacturer
Idealin Fogging Systems is largest and most successful manufacturer of humidifiers and foggers. Here you can see our products like humidifiers and foggers.
IKEUCHI's AKIMist"E" Dry Fog Humidification System provides uniform stable humidity, and expect the following effects. 1. Prevents ESD damege, static issues(Ex. Picking Failure) 2. Stable screen printing performance by keeping solder paste in goo
A product which ensures droplet free humidification in any application. It works on the centrifugal principle and can effectively break the supplied water in very fine particle size of 5 ~ 10 microns. http://idealin-fogging.com/humidifier.html
Electronics Forum | Fri Sep 13 13:55:11 EDT 2013 | rangarajd
Hi, I'm looking for an inexpensive humidifier solution for out 25k sq.ft facility. A closed loop standalone system that can maintain the humidity between 40 - 50 RH. Thank you
Electronics Forum | Wed Nov 09 09:45:34 EST 2011 | dyoungquist
The white haze is most likely coming from your ultrasonic air humidifiers. I have seen this from a home unit that left a white residue on furniture in the house. What is your water source for the humidifiers? If it is hard water you will get more
Used SMT Equipment | Soldering - Reflow
Rehm Siflow Model 3300 Reflow Oven, Nitrogen Capable, w/ AEC Application Engineering PSA Series Air Cooled Portable Water Chiller Model PSA-3Q, S/N 30H0107, Armstrong Series HC4000 HumidiLean Humidifier w/ Assoc. Oven Coolers & Filters, Wesco 440-Lb
Industry News | 2021-08-16 04:54:13.0
Industrial Chiller The chiller, whose full name is the evaporative cooler, is also known as the air cooler, water-cooled air conditioner, industrial air conditioner, energy-saving, and environmental-protection air conditioner, and air conditioning fan.
Industry News | 2021-12-07 20:24:41.0
Variable frequency drive belongs to electronic products, which were composed of many components. An electronic product will not correctly work if any component goes wrong. The Common failures of frequency converters are overvoltage, overload, overcurrent and overheating. They are generally caused by improper use and the operating environment. Meanwhile, there's a particular service life for electronic products. The aging of the product will be more evident as the use of time increases.
Technical Library | 2019-05-21 00:21:26.0
Continue to talk about the dust removal from temperature humidity test chamber. Cleaning and maintenance: 1) Pls remove internal impurities inisde chamber before operation. 2) The power distribution room should be cleaned at least once a year, and the dust can be removed by vacuum cleaner. 3) The exterior chamber must also be cleaned more than once a year, which can be wiped with soapy water. Inspection and maintenance of humidifier: The water storage in humidifier should be replaced once a month to ensure clean water quality, humidifying water tray should be cleaned once a month to ensure smooth flow of water. The inspection of over-temperature protector:during the test: If the temperature is over 20 ℃ ~ 30 ℃ than the maximum value setted,the power supply of the heater will stop, the "OVERHEAT" overt-emperature warning light will automatically turn on but the fan is still in operation, if the equipment runs without operator around,the operator should check the over-temperature protector in advance to ensure wether it has been setted properly before start [wet ball over-temperature protector set to 120 ℃].
Technical Library | 2019-05-06 23:13:09.0
Temperature and humidity test chamber has brought a lot of help to many industrial enterprises, but while it brings convenience to us, we should also take good care of them, otherwise they may be brought into the end-of-life phase ahead of time. The way of maintenance is also very simple. After daily use, the equipment is cleaned regularly, but the cleaning of the test chamber is also very skillful. If the operation is wrong, it may also lead to equipment failure. Let‘s learn how to extend the service life of the temperature and humidity test box together. 1, Pls clean the working room with water after each use, then dry the interior with dry cotton cloth. 2, Pls regularly remove dust from the evaporator inside the equipment, and periodically wipe the equipment to ensure clean and tidy. 3, When doing the test, the sample should be uniformly placed onto sample shelves,and the vent should not be blocked to prevent the influence of the test 4, It is necessary to pay attention to the cleaning of water tanks in peacetime, after the test or when the equipment is not intended to be used for a long time, all the water in the tank should be discharged, otherwise it will lead to the formation of scale inside the tank. The water used in the temperature and humidity test chamber must be pure or distilled water, or long-term use may result in a humidifier or internal pipe clogging. Above are the usual use notice of temperature and humidity test chamber, if customer adhere to the above several points,it is really able to prolong the service life of the equipment.
Events Calendar | Thu Jul 20 00:00:00 EDT 2023 - Thu Jul 20 00:00:00 EDT 2023 | Suwanee, Georgia USA
Atlanta Chapter Technical Meeting: The Science of Humidity Control in Manufacturing