Technical Library: 2hand measurement instruments (Page 1 of 1)

Evaluating Automated Wafer Measurement Instruments

Technical Library | 1999-08-05 09:34:44.0

This document demonstrates a sequential process of evaluating automated wafer instruments and discusses why this approach is useful for studying instruments that have automation features such as loading and focusing mechanisms. The methodology specifies a series of experiments consisting of two or more capability studies followed by a stability study. Each experiment achieves a separate goal, yet combines with the others in providing information needed to assess the usefulness of the instrument.

SEMATECH

Different Types of Pressure Transmitters, Working Principle, and How to Select Pressure Transmitter

Technical Library | 2021-11-25 01:24:20.0

Pressure transmitter is a kind of pressure measuring instrument widely used in many transmitters. It is widely used in petroleum, chemical, metallurgy, food, electric power, medicine, papermaking, textile and other industries. It is mainly used to detect the differential pressure, pressure, absolute pressure and liquid level of fluid.

OKmarts Industrial Parts Mall

Introduction to Automated Test Fixtures

Technical Library | 2022-05-02 21:35:53.0

Testing of electronic assemblies involves three elements: the device under test, test equipment, and fixturing to make the connections between them. The challenge for a test engineer building a sophisticated test system is that instrumentation may need to measure thousands of test points through the mechanical interconnect.

Circuit Check, Inc.

Creating Reusable Manufacturing Tests for High-Speed I/O with Synthetic Instruments

Technical Library | 2020-07-08 20:05:59.0

There is a compelling need for functional testing of high-speed input/output signals on circuit boards ranging from 1 gigabit per second (Gbps) to several hundred Gbps. While manufacturing tests such as Automatic Optical Inspection (AOI) and In-Circuit Test (ICT) are useful in identifying catastrophic defects, most high-speed signals require more scrutiny for failure modes that arise due to high-speed conditions, such as jitter. Functional ATE is seldom fast enough to measure high-speed signals and interpret results automatically. Additionally, to measure these adverse effects it is necessary to have the tester connections very close to the unit under test (UUT) as lead wires connecting the instruments can distort the signal. The solution we describe here involves the use of a field programmable gate array (FPGA) to implement the test instrument called a synthetic instrument (SI). SIs can be designed using VHDL or Verilog descriptions and "synthesized" into an FPGA. A variety of general-purpose instruments, such as signal generators, voltmeters, waveform analyzers can thus be synthesized, but the FPGA approach need not be limited to instruments with traditional instrument equivalents. Rather, more complex and peculiar test functions that pertain to high-speed I/O applications, such as bit error rate tests, SerDes tests, even USB 3.0 (running at 5 Gbps) protocol tests can be programmed and synthesized within an FPGA. By using specific-purpose test mechanisms for high-speed I/O the test engineer can reduce test development time. The synthetic instruments as well as the tests themselves can find applications in several UUTs. In some cases, the same test can be reused without any alteration. For example, a USB 3.0 bus is ubiquitous, and a test aimed at fault detection and diagnoses can be used as part of the test of any UUT that uses this bus. Additionally, parts of the test set may be reused for testing another high-speed I/O. It is reasonable to utilize some of the test routines used in a USB 3.0 test, in the development of a USB 3.1 (running at 10 Gbps), even if the latter has substantial differences in protocol. Many of the SI developed for one protocol can be reused as is, while other SIs may need to undergo modifications before reuse. The modifications will likely take less time and effort than starting from scratch. This paper illustrates an example of high-speed I/O testing, generalizes failure modes that are likely to occur in high-speed I/O, and offers a strategy for testing them with SIs within FPGAs. This strategy offers several advantages besides reusability, including tester proximity to the UUT, test modularization, standardization approaching an ATE-agnostic test development process, overcoming physical limitations of general-purpose test instruments, and utilization of specific-purpose test instruments. Additionally, test instrument obsolescence can be overcome by upgrading to ever-faster and larger FPGAs without losing any previously developed design effort. With SIs and tests scalable and upward compatible, the test engineer need not start test development for high-speed I/O from scratch, which will substantially reduce time and effort.

A.T.E. Solutions, Inc.

Focus on Biosensors

Technical Library | 2016-10-24 15:14:23.0

Biosensors – a new Sensor Type from IST AG What are Biosensors? A biosensor is a device capable of detecting a certain substance or analyte with high specificity. Examples of such analytes are glucose, lactate, glutamine and glutamate. Most biosensors measure the concentration of an analyte in an aqueous solution, usually producing an electrical signal, which is proportional to the analyte’s concentration in its measuring range. An enzymatic biosensor comprises an enzyme, which recognizes and reacts with the target analyte generating a chemical signal, a transducer, which produces a physical signal out of that chemical one, and an electronic amplifier, which conditions and amplifies the signal. Biosensors allow the analysis in complex biological media. The detection of a large number of compounds is of great relevance not only for scientific research but also for process control in the chemical and food industry. It is also indispensable in the health care field for the diagnosis and treatment of diseases and monitoring of illnesses. The pharmaceutical and biotechnology industries greatly desire frequent to continuous analysis of biological media. Such analyses are conducted with the aid of analytical instruments like HPLC systems, which, although robust and reliable, are expensive and have a limited suitability for online operation. For this reason, the acquisition of Jobst Technologies GmbH positions IST AG as a key provider of high-performance and reliable online biosensors.

Innovative Sensor Technology, USA Division

Factors That Influence Side-Wetting Performance on IC Terminals

Technical Library | 2023-08-04 15:27:30.0

A designed experiment evaluated the influence of several variables on appearance and strength of Pb-free solder joints. Components, with leads finished with nickel-palladium-gold (NiPdAu), were used from Texas Instruments (TI) and two other integrated circuit suppliers. Pb-free solder paste used was tin-silver-copper (SnAgCu) alloy. Variables were printed wiring board (PWB) pad size/stencil aperture (the pad finish was consistent; electrolysis Ni/immersion Au), reflow atmosphere, reflow temperature, Pd thickness in the NiPdAu finish, and thermal aging. Height of solder wetting to component lead sides was measured for both ceramic plate and PWB soldering. A third response was solder joint strength; a "lead pull" test determined the maximum force needed to pull the component lead from the PWB. This paper presents a statistical analysis of the designed experiment. Reflow atmosphere and pad size/stencil aperture have the greatest contribution to the height of lead side wetting. Reflow temperature, palladium thickness, and preconditioning had very little impact on side-wetting height. For lead pull, variance in the data was relatively small and the factors tested had little impact.

Texas Instruments

Factors That Influence Side-Wetting Performance on IC Terminals

Technical Library | 2024-04-08 15:46:36.0

A designed experiment evaluated the influence of several variables on appearance and strength of Pb-free solder joints. Components, with leads finished with nickel-palladium-gold (NiPdAu), were used from Texas Instruments (TI) and two other integrated circuit suppliers. Pb-free solder paste used was tin-silver-copper (SnAgCu) alloy. Variables were printed wiring board (PWB) pad size/stencil aperture (the pad finish was consistent; electrolysis Ni/immersion Au), reflow atmosphere, reflow temperature, Pd thickness in the NiPdAu finish, and thermal aging. Height of solder wetting to component lead sides was measured for both ceramic plate and PWB soldering. A third response was solder joint strength; a "lead pull" test determined the maximum force needed to pull the component lead from the PWB. This paper presents a statistical analysis of the designed experiment. Reflow atmosphere and pad size/stencil aperture have the greatest contribution to the height of lead side wetting. Reflow temperature, palladium thickness, and preconditioning had very little impact on side-wetting height. For lead pull, variance in the data was relatively small and the factors tested had little impact.

Texas Instruments

  1  

2hand measurement instruments searches for Companies, Equipment, Machines, Suppliers & Information

Pillarhouse USA for Selective Soldering Needs

Training online, at your facility, or at one of our worldwide training centers"
Sell Used SMT & Test Equipment

High Throughput Reflow Oven
High Throughput Reflow Oven

High Resolution Fast Speed Industrial Cameras.
Fully Automatic BGA Rework Station

"Find out how you can receive priority in SMTnet Search with out Sponsor membership."